LQHDR 1000kV/10kΩ/1A Damping Resistor: Ultra-High Voltage Performance & Thermal Stability

Technical specifications for the LQHDR1000kV/10kΩ/1A damping resistor featuring ONAN cooling, 100K max temperature rise, and 60-minute continuous operation at full load.


  • Negotiated Price
  • Lead time: 60days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHDR1000kV/10kΩ/1A Damping Resistor: Engineering Excellence

Electrical Specifications

ParameterValueStandard
Rated Voltage1000kV ACIEC 60273
Nominal Resistance10kΩ ±0.75%IEEE 4-2013
Rated Current1A continuousIEC 60076
Power Rating5kWThermal Class B
Frequency50HzIEC 60060-1

Thermal Performance & Cooling System

  • Temperature Rise: <100K after 60-min continuous operation at 100% load

  • Cooling Method: ONAN (Oil Natural Air Natural)

  • Thermal Stability: Mechanical integrity maintained at peak temperatures

  • Breakdown Protection: Non-damaging insulation failure mode

The mineral oil-based cooling system ensures uniform heat distribution even at 1000kV operation.

Continuous Operation Capability

Full-Power Endurance: 60 minutes uninterrupted operation at:

  • 1000kV rated voltage

  • 1A rated current

  • 5kW power dissipation

Safety & Reliability Features

  • Fault-Tolerant Insulation: Non-catastrophic failure mode during breakdown

  • Thermal Endurance: Structural integrity maintained at operational temperatures

  • Pressure Relief: Explosion-proof diaphragm for oil expansion

  • Creepage Distance: 30mm/kV (30m total) with silicone composite bushings

Ultra-High Voltage Applications

  • UHV transformer impulse testing (IEC 60076)

  • 1000kV+ transmission line research facilities

  • Nuclear fusion reactor power supplies

  • High-energy physics laboratory setups

  • Lightning impulse generators (IEC 61083-1)

ONAN Cooling System Details

  • Oil Volume: 350L mineral oil (IEC 60296)

  • Radiator Surface: 12m² corrugated fins

  • Thermal Gradient: <15°C between oil and ambient

  • Maintenance: 5-year oil replacement interval

Operational Protocols

  1. Pre-test oil dielectric strength verification (min 60kV/2.5mm)

  2. Thermal imaging at 30-minute intervals during operation

  3. Post-operation cooldown period: 120 minutes minimum

  4. Annual dissolved gas analysis (DGA) for oil quality

Compliance & Certification

  • IEC 60273: High-voltage resistors

  • IEEE 4-2013: HV testing standards

  • EN 60076-14: Liquid-immersed transformer standards

  • IEC 61010-1: Safety requirements