High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Cable and line Testing Instrument

LQHV-550 Wireless Insulator Tester | 1000kV Live Line Voltage Distribution Analyzer

100m-range wireless insulator tester for 0-1000kV lines. Features universal joint probe, EMC shielding, and live detection of faulty insulators per IEC 61481 standards.


  • US$1.00; Negotiated Price
  • Lead time: 30days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHV-550 Wireless Insulator Voltage Distribution Detection System

Live Line Insulator Condition Assessment

This EMC-certified wireless detector identifies failed insulator discs on energized lines up to 1000kV. The 100m transmission range and articulated probe enable safe testing of hard-to-reach suspension strings.

Technical parameters

measurement voltage range0~40kV (special voltage can be customized)
measurement error≤±1%
resolution0.01kV
sampling rate10 times/sec
working current≤120mA (handheld), ≤40mA (detector)
Power Supply2 section 1.5v no.5 dry battery (handheld)
2 section 1.5v no. 7 dry cell (detector)
sustainable working hours≥12hours

detector and handheld line-of-sight

transmission distance

≤100m(sufficient power supply)
Displaypositive display LCD, clearly visible in the sun
working temperature-35℃~+60℃
storage temperature-40℃~+65℃
Relative humidity≤90%RH no condensation

Field Detection Technology

1. Articulated Probe System

  • Adjusts to any suspension angle (0-90°)

  • 1.5m insulated extension rod

  • Non-contact capacitive coupling

2. Wireless Data Transmission

  • 2.4GHz FHSS (100m range)

  • Real-time voltage waveform display

  • 20ms refresh rate

Fault Identification Features

Zero-Resistance Detection

Flags defective insulators when:

  • Voltage drop

    <5% of="" adjacent="" units="">
  • Phase angle deviation >20°

String Imbalance Analysis

  • Compares voltage distribution curves

  • Detects pollution flashover risks

  • Identifies cracked porcelain discs

Typical Applications

  • 500kV+ transmission line maintenance

  • Composite insulator condition checks

  • Pre-outage insulator string audits

  • Tower window inspection

3-Step Operation

  1. Position probe near insulator string

  2. Auto-capture voltage distribution

  3. Review graphical results on handheld

Safety Certifications

  • IEC 61481 (Live working)

  • ANSI/ASTM F711 (Insulated tools)

  • IP54 weather resistance