Cable and line Testing Instrument
LQAG-8000 Wireless High Voltage Phase Detection System
Live Line Phasing Without Electrical Contact
This EMC-compliant wireless tester performs live phase verification up to 500kV using dual-shielded radio transmission (150m range). Eliminates the risks of traditional hardwired phase checks.
Product Parameters
Technical parameters
Test voltage | 10V-500kV, applicable to different voltage levels |
Accuracy | self calibration error ≤±3° |
Sampling rate | 10 times/second |
Date and time setting | adjust the date and time to facilitate users to browse and view historical data |
Backlight time setting | normally on, normally off, can be set within 0-999 seconds |
Automatic shutdown setting | it can be set within 0 to 999 minutes |
Qualitative measurement | display by acousto-optic signal |
quantitative measurement | real-time display of phase Angle difference, error ≤5° |
Phase sequence check | positive phase sequence, negative phase sequence (120°, 240°) |
parameters
The measured voltage | 10V-500kV |
The power supply | Handheld: No.5 AA alkaline battery 2 (1.5V) |
X and Y detectors: No. 7 AA alkaline battery 3 (1.5V) | |
Wireless transmission distance | Visibility 150 m |
In phase | Phase Angle offset ≤20° (threshold 0-90°, can be set by yourself) |
Heterogeneous | Phase Angle offset > 20° (within threshold 0-90°, can be set by oneself) |
Display accuracy | Quantitative measurement ≤5° |
Phase Angle resolution | 1 ° |
Phase sequence measurement | The indicated phase sequence was determined by 120° clockwise /240° counterclockwise |
Display | Positive display LCD, can be clearly displayed under the sun |
Operating temperature | - 35 ℃ - + 50 ℃ |
Storage temperature | To 40 ℃ - + 55 ℃ |
Relative humidity | ≤ 95% RH without condensation |
Handsets | 0.31 kg |
X detector | 0.16 kg |
Y detector | 0.16 kg |
Core Technologies
1. Dual-Shielded Radio Transmission
Penetrates substation EMI (100V/m immunity)
FCC-optimized antennas for obstacle penetration
Frequency-hopping spread spectrum (FHSS)
2. Intelligent Phase Analysis
Acoustic/visual phase indicators
Auto-compensation for line capacitance
On-the-fly calibration
Field Operation Benefits
Safety Redefined
No galvanic connection required:
10cm minimum approach distance
CAT IV 600V rated
Grid-Smart Features
Identifies incorrect phase rotation
Detects cross-circuit phasing errors
Validates transformer vector groups
Three-Component System
X Detector - Clamps onto Phase A
Y Detector - Clamps onto Phase B/C
Handheld Unit - Displays comparative phasor diagram
Typical Applications
Substation bus phasing during maintenance
Parallel feeder synchronization checks
Generator-to-grid phase matching
Underground cable phase verification
⚠️ Critical Note
Always verify detector voltage rating before use on >500kV systems. Not for DC circuit phasing.