≤800kV Range
LQHIVG 600KV-30KJ Impulse Voltage Generator: Technical Specifications & IEC Compliance
Overview
The LQHIVG 600KV-30KJ Impulse Voltage Generator is engineered for precision high-voltage impulse testing. With a 600KV rated voltage and 30kJ energy capacity, it delivers reliable performance in compliance with international standards for electrical insulation testing.
Compliance with International Standards
This generator meets critical global standards for high-voltage testing:
IEC 60060-1 & 2: General test requirements and measuring systems
IEC 61083-1 & 2: Digital recorder specifications for impulse tests
ANSI/IEEE 4a, 376, 1122: Impulse strength measurement protocols
ASTM D69-D2484 & D2518: Electrical insulation testing guidelines
Technical Parameters
Parameter | Specification |
---|---|
Rated Voltage | ±600kV |
Rated Charging Voltage | ±150kV |
Rated Energy | 30kJ |
Impulse Capacitor | 1.33µF/75kV per stage |
Stages | 4 stages (7.5kJ/stage) |
Waveform Parameters |
|
Voltage Efficiency | ≥90% (no load) |
Synchronous Range | 10-100% rated voltage (±20% polarity) |
Load Range | 300pF–3000pF |
Performance Features
Precision Control: Charging voltage instability
<±1.0%<>Rapid Cycling: 60-120s discharge cycles (depending on voltage)
Safety Compliance: ≤2% uncontrolled discharge rate
DC Charging: 8kVA bilateral asymmetric charging with 0.3A average current
Applications
Ideal for:
Transformer and substation impulse testing
Insulation material validation (ASTM D2518)
Power equipment certification to IEC 60060
Lightning surge simulation in R&D labs