High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

≤800kV Range

LQHIVG 500KV-25KJ Impulse Voltage Generator | High-Voltage Testing Solution

Technical specifications for the LQHIVG 500KV-25KJ Impulse Voltage Generator with IEC/IEEE/ASTM compliance. Features 500kV output, 25kJ energy, and ≤1% voltage instability for precision dielectric testing.


  • US$ 19,479.00
  • Lead time: 60 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHIVG 500KV-25KJ Impulse Voltage Generator | High-Voltage Testing Solution

Ultra-High Voltage Testing Platform

The LQHIVG 500KV-25KJ Impulse Voltage Generator delivers precision dielectric testing at extreme voltages. With 500kV output and 25kJ energy capacity, this 4-stage system validates insulation integrity in power transformers, switchgear, and transmission equipment under standardized lightning impulse conditions.

Global Standards Compliance

Certified for international testing protocols including:

  • IEC 60060-1/2-2010: High-voltage test techniques

  • IEC 61083-1/2: Digital measurement systems

  • ANSI/IEEE 4a-2001: High-voltage testing methods

  • ASTM D2484/D2518: Electrical insulation standards

Core Technical Specifications

ParameterSpecification
Rated Voltage±500kV
Stage Configuration4 stages
Rated Energy25kJ
Stage Voltage±100kV
Stage Energy5kJ per stage
Impulse Capacity0.2μF
Power Supply220V AC

Control System Performance

FeaturePerformance
Trigger Range≥20% rated voltage
Synchronization Malfunction Rate<5%
Voltage Instability≤1% peak output
Sparking Range10-100% Un
Minimum Output Voltage<15% Un

Operational Efficiency

Cycling Performance

  • High-voltage mode (> 2/3 rated voltage): 90s charge/discharge cycles

  • Standard mode (< 2/3 rated voltage): 45s charge/discharge cycles

System Reliability

  • ±100kV stage voltage stability

  • Optimized 4-stage capacitor configuration (1μF/100kV per stage)

  • 220V power compatibility for lab/field use

Industrial Applications

  • Power transformer impulse withstand testing (IEC 60076)

  • High-voltage circuit breaker certification

  • Transmission line equipment validation

  • Renewable energy substation commissioning

Safety & Calibration

  1. Annual calibration per IEC 61083-2 requirements

  2. Strict adherence to IEEE 4a safety margins

  3. Dielectric absorption testing per ASTM D2518

  4. Mandatory safety interlocks for >1kV operation

Performance Validation

All impulse waveforms comply with IEC 60060-1 requirements. System verification includes:

  • NIST-traceable voltage calibration

  • Oscilloscopic waveform analysis

  • Temperature-compensated measurements (23±5°C)

>>>WhatsApp Communication<<<