≤800kV Range
LQHIVG 400KV-10KJ Four-Stage Impulse Generator: Ultra-High Voltage Testing
The LQHIVG 400KV-10KJ Impulse Voltage Generator delivers extreme high-voltage testing capabilities through its innovative four-stage design. Engineered for precision lightning impulse and chopped wave testing, this system serves industrial test facilities, national research centers, and universities with IEC 60060-compliant performance for insulation analysis and pollution studies.
Standards Compliance
IEC 60060-1:2010 - General test requirements
IEC 60060-2:2010 - Measuring systems
ANSI/IEEE 4a:2001 - HV testing techniques
ANSI/IEEE 1122:2007 - Digital recorder standards
GB311/GB16927 - Waveform compliance
Technical Specifications
Parameter | Specification |
---|---|
Rated Voltage | ±400kV |
Stage Configuration | 4 stages |
Stage Voltage | ±100kV per stage |
Total Energy Capacity | 10kJ (2.5kJ per stage) |
Stage Capacitors | 4 × 100kV 0.5μF |
Total Impulse Capacitance | 0.125μF |
Load Capacitance Range | 300-3000pF |
Voltage Stability | ±1.0% charging deviation |
Precision Waveform Generation
Lightning Impulse Full Wave (1.2/50μs)
Front Time: 1.2μs ±30%
Tail Time: 50μs ±20%
Peak Oscillation: <5% amplitude
Lightning Impulse Chopped Wave
Chopping Time: 2-5μs
Peak Voltage Deviation: <3%
Performance Characteristics
Voltage Range: 10-100% Un sparking range
Minimum Output: >10% rated voltage (40kV)
Synchronous Control:
20-100% voltage operation
<25% polarity deviation
<5% out-of-control rate
Duty Cycle:
120s interval at >66% rated voltage
60s interval at <66% rated voltage
Four-Stage Design Advantages
Ultra-High Voltage Output - 400kV capacity for EHV equipment testing
Precision Capacitor Bank - 0.125μF total capacitance with balanced staging
Advanced Chopped Wave Control - <3% peak deviation for accurate insulation breakdown studies
Compact Energy Management - 2.5kJ per stage for thermal stability
Research & Industrial Applications
Equipment Certification
Lightning impulse full wave tests
Chopping wave withstand validation
Switching impulse analysis
Advanced Insulator Studies
Impulse flashover testing
Non-uniform pollution characteristic research
Insulation coordination under contaminated conditions
Operational Reliability
Features multi-stage synchronous control with <5% failure rate and thermal-optimized duty cycling. Complies with IEC 61083-2 for measurement accuracy, with NIST-traceable calibration ensuring consistent performance at 400kV operations.
Ideal For
National high-voltage research facilities
University power engineering labs
Transformer and switchgear manufacturers
Transmission line component test centers