≤800kV Range
LQHIVG 300KV-20KJ High-Capacity Impulse Generator: Advanced Testing Specifications
The LQHIVG 300KV-20KJ Impulse Voltage Generator represents cutting-edge high-voltage testing technology with its three-stage design and 20kJ energy capacity. Engineered for precision lightning impulse and chopped wave testing, this system exceeds IEC 60060 standards while offering enhanced control features for demanding power equipment certification.
Standards Compliance
IEC 60060-1:2010 - General test requirements
IEC 60060-2:2010 - Measuring systems
ANSI/IEEE 4a:2001 - HV testing techniques
ANSI/IEEE 1122:2007 - Digital recorder standards
GB311/GB16927 - Waveform compliance
Technical Specifications
Parameter | Specification |
---|---|
Rated Voltage | ±300kV |
Stage Configuration | 3 stages |
Stage Voltage | ±100kV per stage |
Total Energy Capacity | 20kJ (6.67kJ per stage) |
Stage Capacitors | 3 × 100kV 1.334μF |
Rated Impulse Capacity | 0.445μF |
Voltage Stability | ±1.0% charging deviation |
Precision Waveform Generation
Lightning Impulse Full Wave (1.2/50μs)
Front Time: 1.2μs ±30%
Tail Time: 50μs ±20%
Amplitude Deviation: <3%
Peak Oscillation: <5%
Voltage Efficiency: ≥90% (no load)
Lightning Impulse Chopped Wave
Chopping Time: 2-5μs
Complies with GB311/GB16927
Advanced Control Features
Synchronous Range: 10-100% voltage
Polarity Control: <20% deviation
Discharge Reliability: <2% out-of-control rate
Sparking Range: 10-100% Un
Minimum Output: ≥10% rated voltage (30kV)
Optimized Performance Characteristics
Feature | Specification |
---|---|
Voltage Reference Accuracy | <±1.0% deviation |
Duty Cycle (≥70% voltage) | 120s charge/discharge interval |
Duty Cycle (<70% voltage) | 60s charge/discharge interval |
Minimum Discharge Time | ≥60s at maximum voltage |
Three-Stage Engineering Advantages
High-Energy Density - 20kJ total capacity with optimized 1.334μF capacitors
Enhanced Synchronization - <2% discharge failure rate for reliable testing
Precision Voltage Control - Dual stability metrics (<±1% charging and reference deviation)
Extended Voltage Range - Operates down to 10% rated voltage (30kV)
Industrial Applications
EHV transformer and reactor impulse testing
Power transmission equipment certification
Surge arrester performance validation
Insulation coordination studies with chopped wave simulation
Operational Reliability