High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

<1000kV Range

LQHID-600KV-300pF-Weak-Damping-Capacitor-Voltage-Divider-Specifications

Discover the LQHID 600KV-300pF weak damping capacitor voltage divider featuring MWF600 impulse capacitors, multistage damping resistors, and GB/T311.1 compliance for precise high-voltage testing.


  • US$ 5,526.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHID 600KV-300pF Weak Damping Capacitor Voltage Divider: Technical Specifications

Advanced Design Features

The LQHID 600KV-300pF features an innovative weak damping capacitive design with MWF600 impulse capacitors and multistage distributed damping resistors. Its non-inductive structure ensures accurate waveform measurement, while the polyurethane housing provides superior protection and mobility.

  • MWF600 Impulse Capacitor: High-performance core component for stable 600kV operation

  • Multistage Damping Resistors: Precisely distributed for optimal waveform control

  • Non-Inductive Construction: Parallel-connected low-voltage arm capacitors eliminate measurement distortion

  • Durable Polyurethane Housing: Lightweight yet robust protection with integrated corona covers

Technical Specifications

ParameterSpecification
Rated Voltage+600kV
HV Arm Capacitance300pF
Voltage Ratio2000:1
Partial Response Time (Tas)≤100nS
Over-Impulse Limit (β)≤20%
Scale Factor Uncertainty (Kg)≤±1%
Construction HeightApprox. 2.1m (with corona covers)
MobilityMovable polyurethane design

Performance Advantages

  1. Ultra-Fast Response: ≤100ns response time captures lightning impulse transients with precision

  2. Exceptional Accuracy: ≤±1% scale factor uncertainty for reliable measurements

  3. Superior Waveform Fidelity: Non-inductive design preserves signal integrity up to 600kV

  4. Rugged Construction: Polyurethane housing withstands harsh field conditions

Standards Compliance

Fully compliant with international and Chinese standards:

  • GB/T 311.1: Insulation coordination standards

  • GB/T 16927: High-voltage test techniques

  • IEC 60060-1: High-voltage test procedures

  • Square wave response meets all GB/T requirements

Typical Applications

  • Lightning impulse testing of power transformers

  • On-site commissioning of 600kV-class equipment

  • High-voltage laboratory calibration

  • Transient overvoltage research

  • Switchgear impulse withstand verification

Operational Recommendations

  • Maintain minimum 3m clearance during 600kV operation

  • Use matched impedance coaxial cables (≤5m length recommended)

  • Perform quarterly dielectric tests on HV capacitors

  • Inspect corona covers before each high-voltage test

  • Store in controlled environment (10°C-30°C, humidity ≤70%)