LQHID 500KV/300pF Weak Damping Capacitor Voltage Divider: Technical Specifications

Product Overview

The LQHID 500KV/300pF weak damping capacitor voltage divider features a compact single-stage design optimized for precision high-voltage measurements in field and laboratory settings. With a height of only 1.6m and manual portability, this instrument delivers exceptional performance in impulse testing applications up to 500kV.

Key Specifications

ParameterSpecification
Rated Voltage+500kV
HV Arm Capacitance300pF
Voltage Ratio1000:1
Partial Response Time (Ta)≤100nS
Overshoot Limit (β)≤20%
Voltage Ratio Instability (Kes)≤1%
HV Arm ConstructionSingle-stage capacitor
Unit HeightApproximately 1.6m
PortabilityManually movable

Design Advantages

  • Compact Single-Stage Design: 1.6m height enables operation in confined spaces without performance compromise

  • Field-Portable Operation: Lightweight construction allows manual relocation between test sites

  • Weak Damping Technology: Minimizes waveform distortion for accurate impulse measurements

Performance Features

  1. Ultra-Fast Response: ≤100ns partial response time captures transient events with precision

  2. Stable Output: ≤1% ratio instability ensures measurement consistency across tests

  3. Controlled Overshoot: ≤20% overshoot limit maintains waveform integrity during high-voltage surges

  4. High-Accuracy Scaling: 1000:1 voltage ratio provides reliable signal reduction for instrumentation

Typical Applications

  • Impulse voltage testing of transformers and bushings

  • On-site commissioning of high-voltage switchgear

  • Research laboratory measurements

  • Power quality monitoring in substations

  • Dielectric strength verification

Operational Guidelines

  • Maintain minimum clearance of 2.5m from grounded surfaces during 500kV operation

  • Use shielded coaxial cables with impedance matching to minimize signal reflections

  • Perform monthly capacitance verification using certified LCR meters

  • Store in climate-controlled environments (15°C-25°C) when not in use

Compliance Standards

Designed to meet international testing requirements:

  • IEC 60060-1: High-voltage test techniques

  • IEEE Std 4: Standard for high-voltage testing

  • ANSI/NETA ATS: Acceptance testing specifications