<1000kV Range
LQHID 400KV/400pF Weak Damping Capacitor Voltage Divider
Engineered for ultra-high-voltage testing applications, the LQHID 400KV/400pF Capacitor Divider delivers precision measurements up to 400kV. Featuring advanced corona prevention, distributed damping technology, and a mobile industrial base, this solution is essential for power transmission testing and high-voltage research.
Technical Specifications
Parameter | Specification |
---|---|
Rated Voltage | +400kV |
Configuration | Single-stage multistage capacitors |
Standard Lightning Wave | +400kV impulse withstand |
Rated Capacitance | 400pF ±5% |
Partial Response Time (Tα) | ≤100 nanoseconds |
Overshoot (β) | ≤20% |
Scale Factor Uncertainty (Ks) | ≤±1% |
Voltage Ratio | 1000:1 |
Standards Compliance | GB311 (square wave response) |
Dimensions | Custom high-strength mobile base |
Top Electrode Material | Stainless steel tube |
Advanced Design Features
Multistage Capacitor System
Series-connected pulse capacitors with distributed damping resistors eliminate inductance for accurate high-frequency response at 400kV.
Corona Prevention Technology
Optimized corona cover prevents discharge during 400kV+ switching impulses
Stainless steel top electrode minimizes abnormal flashover
Cross-profile design for positive impulse wave stability
Industrial Mobile Base
High-strength movable platform with fixed braces
Polyurethane wheels (2500kg load capacity)
Field-installable top electrode for transportation
Performance Specifications
Characteristic | Performance |
---|---|
Low-Voltage Arm | Parallel non-inductive capacitors |
Frequency Response | DC to 10MHz |
Dielectric Strength | 600kV (150% overvoltage withstand) |
Impulse Polarity | Positive (+400kV) |
Standards Compliance
Full GB311 square wave response compliance (0-9.9μS)
Compatible with IEC 60060-1 impulse test standards
Designed for IEEE 4 switching surge measurements
Industrial Applications
Ultra-HV Transmission: 400kV lightning impulse tests on transformers
Substation Testing: GIS circuit breaker switching surge analysis
Power Research: HVDC converter station transient studies
Generator Validation: Insulation testing for turbine generators
Mechanical Construction
Base material: Reinforced carbon steel (2mm thickness)
Electrode: Field-installable 304 stainless steel tube
Wheel system: 180mm polyurethane with dual braking
Corona cover: Optimized for 400kV positive impulses
Operational Safety
4-meter minimum clearance at 400kV operation
Automatic grounding system for capacitor banks
EMI-shielded low-voltage connections
Corona discharge < 10pC at 350kV
Calibration & Maintenance
Factory calibration certificate included
Annual dielectric verification at 500kV AC
Biannual damping resistor network inspection
5-year full system recertification cycle
Technical Advantages
Feature | Benefit |
---|---|
400pF Capacitance | Enhanced signal-to-noise ratio |
Distributed Damping | Minimal waveform distortion |
Field-Installable Electrode | Easier transportation and setup |
Corona Control | Reliable measurements at 400kV |
Support Services
GB311 compliance documentation
On-site installation supervision
Custom calibration for specific test protocols
Lifetime technical consultation