≥1000KV Range
LQHCG 1800KV-600pF Triple-Stage Multiple Chopping Gap System
Next-Generation High Voltage Testing
The LQHCG 1800KV-600pF represents the cutting edge in ultra-high voltage test systems, featuring a revolutionary three-stage design with 600pF capacitance for enhanced energy storage. With 200mm sphere gaps and nanosecond-precision triggering, this system delivers unparalleled performance for critical power equipment validation up to 1800kV.
Technical Specifications
Core Electrical Parameters
Rated Voltage: 1800kV (peak)
Stage Configuration: 3×600kV stages
Rated Capacitance: 600pF ±1.5%
Energy Storage: 972J at full voltage
Mechanical Design
Sphere Gaps: 9 pairs (3 per stage)
Gap Diameter: 200mm semi-sphere
Trigger System: 3-electrode discharge
Trigger Pulse: 10kV, 100ns rise time
Precision Control
Time-Delay Pulse: 250kV adjustable
Chopping Precision: σ<0.1μs deviation
Control Interface: Digital μs-setting
Synchronization: <0.5% stage deviation
Innovative Design Features
Triple-Stage Architecture
3×600kV stages provide superior voltage distribution with 40% reduced field distortion compared to conventional two-stage designs
Enhanced Sphere Gaps
200mm diameter gaps (vs standard 150mm) improve arc stability and increase maintenance intervals by 2-3×
High-Capacity Design
600pF capacitance (50% increase over standard 400pF systems) enables testing of larger capacitive loads
Performance Comparison
Parameter | LQHCG 1800KV-600pF | Conventional 1800kV Systems |
---|---|---|
Stage Count | 3 stages | 2 stages |
Sphere Gap Size | 200mm | 150mm |
Capacitance | 600pF | 400pF |
Trigger Precision | 100ns | 200-500ns |
Certifications & Standards
Compliant with all major international standards:
IEC 60060-1/-2:202X (High-voltage test techniques)
IEEE Std 4-2021 (Standard for HV testing)
GB/T 16927.1-2022 (Lightning impulse tests)
EN 60060-2:202X (Measurement requirements)
Typical Applications
UHV transformer impulse testing (≥800kV class)
HVDC converter station equipment validation
Power capacitor bank destructive testing
Research on next-generation GIS systems
National metrology institute reference standards
Maintenance Protocol
Interval | Action | Tool/Standard |
---|---|---|
Every 50 operations | Sphere gap inspection/cleaning | Anhydrous ethanol, lint-free cloth |
Quarterly | Trigger circuit verification | 10kV pulse measurement fixture |
Annual | Full system calibration | IEC 60060-3 reference divider |
Why Choose This System?
The LQHCG 1800KV-600pF sets new industry benchmarks with its unique combination of triple-stage design, 200mm sphere gaps, and 600pF capacitance. This system delivers 30% greater energy capacity than conventional 400pF units while maintaining sub-0.1μs chopping precision - making it the ultimate solution for UHV research labs and power equipment certification centers.