High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

≥1000KV Range

LQHCG 1800KV-400pF Dual-Stage Chopping Gap | Ultra-High Voltage Test System

Dual-stage 1800kV chopping gap system with 8×150mm sphere gaps, 10kV/100ns trigger pulse, and sub-0.1μs chopping time precision for ultra-high voltage testing applications.


  • US$ 21,312.00
  • Lead time: 60 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHCG 1800KV-400pF Dual-Stage Multiple Chopping Gap System

Industry-Leading High Voltage Testing

The LQHCG 1800KV-400pF sets new benchmarks in ultra-high voltage testing with its dual-stage architecture and nanosecond-precision triggering. Engineered for laboratories requiring 1800kV impulse testing with ≤0.1μs chopping time deviation, this system delivers unmatched stability for critical power equipment validation.

Technical Specifications

Electrical Parameters

Rated Voltage1800kV (peak)
Stage Configuration2×900kV stages
Rated Capacitance400pF ±2%
Chopping Range2-5μS (digitally adjustable)

Mechanical Design

Sphere Gaps8 pairs (4 per stage)
Gap Diameter150mm semi-sphere
Trigger Pulse10kV, 100ns rise time
Time-Delay Pulse250kV adjustable

Performance Metrics

Chopping Precisionσ<0.1μs deviation
Trigger System3-electrode discharge
Pulse AmplifierHigh-performance 10kV output
Control InterfaceDigital time setting

Breakthrough Technology

  • Dual-Stage Voltage Distribution

    2×900kV stages provide superior voltage balancing and reduced field distortion compared to single-stage 1800kV systems

  • Nanosecond Trigger System

    10kV/100ns pulse amplifier ensures reliable initiation even under maximum voltage conditions

  • Precision Time Control

    Digital adjustment of 250kV time-delay pulse enables μs-accurate chopping

Compliance & Certifications

This system meets rigorous international standards:

  • IEC 60060-1 & -2: High-voltage test techniques

  • IEEE Std 4-2013: Standard for HV testing

  • GB/T 16927.1-2011: Lightning impulse tests

  • EN 60060-2: Measurement requirements

Typical Test Applications

  1. Ultra-high voltage transformer impulse testing

  2. HVDC transmission equipment validation

  3. Power capacitor bank withstand tests

  4. Research on 800kV+ GIS systems

  5. National standards laboratory reference

Operational Advantages

FeatureBenefitTechnical Impact
Dual-stage designImproved field uniformityReduces corona loss by ~35%
100ns triggerHigher reliability99.7% first-attempt success rate
Digital controlPrecision timing±0.02μs time-setting resolution

Maintenance Protocol

  1. Monthly sphere gap inspection (clean with anhydrous ethanol)

  2. Quarterly trigger circuit verification

  3. Annual full-system calibration

  4. 5-year dielectric fluid replacement

  5. 10-year comprehensive overhaul

Why This System?

The LQHCG 1800KV-400pF represents the pinnacle of chopping gap technology, combining unprecedented 1800kV capacity with sub-μs precision. Its dual-stage architecture and advanced trigger system make it the preferred choice for national labs, power equipment manufacturers, and research institutions where measurement certainty is non-negotiable.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message