≥1000KV Range
LQHCG 1600KV-400pF Portable Multiple Chopping Gap System
High-Voltage Testing Solution
The LQHCG 1600KV-400pF represents the next generation of portable high-voltage test equipment, combining 1600kV capacity with precision L-C time-delay circuitry. Designed for field and laboratory use, this system features integrated corona rings and exceptional synchronization stability (<2% control sync rate).
Technical Specifications
Core Parameters | |
---|---|
Maximum System Voltage | 1600kV (peak) |
Stage Voltage Rating | 200kV per stage |
Rated Capacitance | 400pF ±3% |
Sphere Gap Configuration | 8 pairs with corona protection |
Chopping Voltage Range | 20% to 100% of rated voltage |
Timing Characteristics | |
Chopping Time Range | 2-6μS adjustable |
Time-Delay Circuit | Precision L-C adjustable network |
Control Sync Rate | <2% deviation |
Mechanical Design | |
Trigger Method | Three-electrode discharge system |
Portability | Integrated transport design |
Corona Protection | Top-mounted corona ring system |
Advanced Features
Precision Timing Control
L-C adjustable circuit delivers microsecond-accurate delays with exceptional temperature stability
Enhanced Safety Design
Integrated corona rings reduce partial discharges by up to 40% compared to standard designs
Modular Voltage Scaling
200kV stage architecture allows flexible configuration for different test requirements
Field-Ready Portability
Compact design reduces transport volume by 30% versus conventional 1600kV systems
Typical Applications
On-site testing of power transformers (IEC 60076)
Lightning impulse withstand tests (IEC 60060-1)
Research on gas-insulated switchgear (GIS) systems
Calibration of high-voltage measurement dividers
Power transmission equipment quality verification
Performance Advantages
Wider Voltage Range: 20-100% chopping voltage scope enables more test scenarios
Improved Synchronization: <2% sync rate ensures test repeatability
Reduced Corona Loss: Patented top-ring design minimizes energy loss
Faster Setup: Portable configuration cuts installation time by 50%
Operation Guidelines
Verify all ground connections before energizing
Adjust L-C circuit for desired time-delay characteristics
Maintain minimum 2.5m clearance during 1600kV operation
Perform weekly sphere gap inspection under heavy use
Store in climate-controlled environment when not in use
Compliance Standards
This system meets or exceeds requirements of:
IEC 60060-1: High-voltage test techniques
IEEE Std 4-2013: Standard for HV testing
GB/T 16927.1-2011: Lightning impulse tests
EN 60060-2: Measurement requirements
Why This System Stands Out
The LQHCG 1600KV-400pF combines unprecedented portability for a 1600kV system with laboratory-grade precision. Its unique L-C adjustable timing circuit and optimized corona protection make it ideal for both field testing and standards laboratory applications where space constraints and measurement accuracy are equally critical.