High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Damping Resistor

HGDR 800kV/2.5kΩ/1A SF6 Damping Resistor | Ultra-HV High-Current Energy Absorption

800kV-rated damping resistor handles 1A continuous current with ≤3pC partial discharge. Features 2.5kW power rating and 20-minute short-circuit capability for extreme HV testing.


  • US$ 8,057.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

HGDR 800kV/2.5kΩ/1A Gas Insulated Damping Resistor

Engineered for the most demanding ultra-high-voltage applications, the HGDR 800kV/2.5kΩ/1A sets new standards with its exceptional 1A current capacity and industry-leading ≤3pC partial discharge performance. This SF6 gas-insulated resistor delivers reliable energy absorption in 800kV test systems, HVDC research, and particle accelerator applications.

Technical Specifications

ParameterSpecification
Rated Voltage800kV DC/AC peak
Nominal Resistance2.5kΩ ±5%
Rated Current1A continuous
Rated Power2.5kW
Frequency50Hz
Partial Discharge≤3pC @ 800kV, ≤2pC @ 640kV
Short-Circuit Duration20 minutes at full rating
Insulation MediumSF6 Gas (0.6MPa)

Breakthrough Performance

1. Extreme Voltage Endurance

  • 800kV continuous operation

  • 880kV (110%) withstand for 60s

  • Multi-stage electrostatic shielding

2. Unmatched Current Handling

  • 1A continuous current rating

  • 2.5kW power dissipation

  • Helical non-inductive winding

3. Ultra-Clean Operation

  • ≤3pC partial discharge at 800kV

  • SF6 gas eliminates corona effects

  • Optimal for sensitive measurements

Engineering Innovations

Resistive Core

  • Vacuum-encapsulated NiCr60 alloy

  • Aluminum nitride ceramic substrate

  • Precision-wound for uniform current density

Gas System

  • 0.6MPa SF6 with moisture control

  • Triple-seal stainless steel enclosure

  • Automatic pressure compensation

Critical Applications

  • UHV transmission line testing (800kV+)

  • HVDC valve hall commissioning

  • Pulsed power system development

  • High-energy physics experiments

Competitive Advantages

  1. Industry-Leading PD: 50% lower than comparable resistors

  2. High Current Density: 1A rating in compact footprint

  3. Thermal Stability: <80K temperature rise at full load

  4. Safety Assurance: Dual-redundant pressure relief

Installation Requirements

Electrical

  • 800kV-rated composite bushings

  • Minimum 3.5m phase-to-ground clearance

Operational

  • 20-minute maximum continuous operation

  • 90-minute minimum cooldown

  • Quarterly gas pressure verification

Certifications

  • IEC 60060-1 (High-voltage testing)

  • IEEE Std 4-2013 (HV techniques)

  • CIGRE TB 815 (UHV equipment)

>>>WhatsApp Communication<<<