High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Damping Resistor

HGDR 270kV/2kΩ/1.5A SF6 Damping Resistor | High-Current HV Energy Dissipation

The HGDR 270kV/2kΩ/1.5A SF6 damping resistor handles 1.5A continuous current with 20-minute short-circuit capability, designed for high-energy pulse absorption in 270kV systems.


  • US$ 4,442.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

HGDR 270kV/2kΩ/1.5A Gas Insulated Damping Resistor

Designed for high-current energy dissipation in ultra-high-voltage systems, the HGDR 270kV series combines 2kΩ precision resistance with exceptional 1.5A current capacity. This SF6 gas-insulated resistor delivers reliable performance in demanding applications requiring both high voltage endurance and robust current handling.

Technical Specifications

ParameterSpecification
Rated Voltage270kV DC/AC peak
Nominal Resistance2kΩ ±5%
Rated Current1.5A continuous
Power Rating405kW peak
Frequency50Hz
Short-Circuit Duration20 minutes at full rating
Insulation MediumSF6 Gas (0.45MPa)
Temperature Range-25°C to +55°C

Key Features

1. High-Current Capability

  • 1.5A continuous current rating

  • 405kW peak power dissipation

  • Low-inductance helical winding design

2. Precision Voltage Control

  • 2kΩ ±5% tolerance across full range

  • Stable performance under pulse loads

  • Minimal resistance drift (<300ppm/°C)

3. Robust Construction

  • Double-walled stainless steel enclosure

  • Copper-tungsten alloy electrodes

  • Automatic pressure relief system

Design Highlights

Resistive Element

  • Nickel-chrome alloy resistance wire

  • Ceramic core with alumina coating

  • Precision-wound for uniform current distribution

Cooling System

  • SF6 gas convection cooling

  • Optimized internal baffle design

  • 30°C/minute cooldown rate

Typical Applications

  • HVDC converter station testing

  • Power transformer impulse testing

  • Pulsed power system loads

  • High-energy physics experiments

Performance Advantages

  1. High Energy Density: 486kJ absorption capacity per cycle

  2. Rapid Response: <1μs reaction to pulse transients

  3. Safety Built-In: Pressure-activated disconnect switch

  4. Maintenance-Free: Sealed for 10+ year service life

Installation Guidelines

Electrical Requirements

  • 270kV-rated silicone rubber bushings

  • Minimum 1.8m phase-to-ground clearance

  • Use equalizing rings for >200kV applications

Operational Protocol

  • Maximum 20-minute continuous operation at 1.5A

  • 45-minute minimum cooldown between cycles

  • Monthly SF6 pressure checks recommended

Compliance Standards

  • IEC 60060-1 (High-voltage test techniques)

  • IEEE Std 4 (Standard for HV testing)

  • ANSI/NETA MTS-2019 (Maintenance testing)

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message