Damping Resistor

HGDR 750kV/5kΩ/0.4A SF6 Damping Resistor | Ultra-High Voltage Energy Dissipation

The HGDR 750kV/5kΩ/0.4A SF6 damping resistor handles 750kV systems with ≤5pC partial discharge, designed for precision energy absorption in ultra-high-voltage testing.


  • US$ 7,602.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

HGDR 750kV/5kΩ/0.4A Gas Insulated Damping Resistor

Engineered for **ultra-high-voltage (UHV) applications**, the **HGDR 750kV/5kΩ/0.4A** damping resistor delivers **precision energy absorption** with **≤5pC partial discharge** at full load. Its **SF6 gas-insulated design** ensures stable performance in **750kV test systems**, making it ideal for **impulse testing, HVDC research, and high-energy physics experiments**.

Technical Specifications

ParameterSpecification
Rated Voltage750kV DC/AC peak
Nominal Resistance5kΩ ±5%
Rated Current0.4A continuous
Rated Power0.8kW
Frequency50Hz
Partial Discharge (PD)≤5pC @ 750kV, ≤3pC @ 600kV
Short-Circuit Duration20 minutes at full rating
Temperature Rise≤80K at 100% load
Insulation MediumSF6 Gas (0.5MPa)

Key Features

1. Ultra-High Voltage Stability

  • 750kV rated voltage with 825kV withstand capability

  • ≤5pC partial discharge ensures measurement accuracy

  • SF6 gas insulation prevents corona discharge

2. Precision Energy Absorption

  • 5kΩ ±5% tolerance for consistent performance

  • Low thermal drift (<200ppm/°C)

  • 0.8kW power dissipation with controlled temperature rise (≤80K)

3. Robust & Maintenance-Free

  • 20-minute short-circuit capability at full load

  • Stainless steel enclosure with double O-ring seals

  • No required servicing for 10+ years

Design & Construction

Resistive Element

  • Special alloy wire (NiCr) for high stability

  • Ceramic core with high thermal conductivity

  • Graded potential rings for uniform field distribution

Cooling & Safety

  • SF6 gas convection cooling (0.5MPa)

  • Pressure relief valve for overload protection

  • Integrated temperature sensors for real-time monitoring

Typical Applications

  • UHV transmission testing (800kV+ systems)

  • HVDC converter station commissioning

  • Pulsed power research (lasers, accelerators)

  • High-voltage capacitor discharge circuits

Performance Advantages

  1. Ultra-Low PD (≤5pC) for noise-free measurements

  2. Controlled Temperature Rise (≤80K) for extended duty cycles

  3. High Reliability (20-minute short-circuit rating)

  4. No Maintenance (sealed SF6 design)

Installation & Usage

Electrical Requirements

  • Use 750kV-rated bushings (silicone rubber recommended)

  • Minimum 3m clearance to grounded objects

Operational Limits

  • 20-minute max operation at 0.4A

  • 60-minute cooldown required between cycles

  • Ambient temperature: -20°C to +50°C

Compliance Standards

  • IEC 60060-1 (High-voltage testing)

  • IEEE Std 4 (HV measurement)

  • EN 62271-203 (SF6-insulated equipment)