High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

>400kVA Rang

HET 400kVA/4.8kV Exciter Transformer | Triple-Range Testing (2.4-4.8kV) with 20-300Hz Frequency

The HET 400kVA/4.8kV Exciter Transformer offers triple voltage ranges (2.4-4.8kV) with 20-300Hz frequency flexibility, electrostatic shielding, and continuous 60-minute operation for demanding test applications.


  • US$ 24,263.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

HET 400kVA/4.8kV Exciter Transformer - Variable Frequency Testing Solution

The HET 400kVA/4.8kV,3.6kV,2.4kV Exciter Transformer delivers exceptional flexibility for low-frequency testing (20-300Hz) with three voltage outputs, independent HV windings, and industrial-grade thermal stability for continuous operation.

Technical Specifications

ParameterSpecification
Rated Capacity400kVA
Frequency Range20-300Hz (Rated 20Hz)
HV Winding Voltage2.4kV, 3.6kV, 4.8kV (Independent)
HV Winding Current166.6A (2.4kV), 111.1A (3.6kV), 83.3A (4.8kV)
LV Winding Voltage2×460V, 2×500V
LV Winding Current2×424.8A
Cooling SystemONAN (Oil Natural Air Natural)
Thermal LimitsContinuous 60min operation:
Winding ≤65K, Oil ≤55K
Noise Level≤60dB
Impedance Voltage<5%

Advanced Design Features

Core & Winding Technology

  • Premium Core Material: D0130-30 cold-rolled silicon steel with ultra-low Bm value

  • Independent HV Windings: Three separate coils for precise voltage selection

  • Electrostatic Shielding: Isolation filter between LV/HV windings

Monitoring & Protection

  • Integrated Measurement: HV-side voltage measurement coil

  • Oil Management System:

    • Expansion tank with moisture absorber

    • Temperature thermograph and level indicator

Structural Advantages

  • Shell-Type Construction: Oil-immersed design with transport-safe components

  • Safety-Spaced Windings: Prevents partial discharge and corona effects

  • Copper Lead Wires: Low-resistance connections for high-current capacity

Performance Benefits

Frequency Flexibility

20-300Hz range for specialized test protocols

High Current Output

166.6A at 2.4kV for demanding loads

Thermal Stability

Continuous 60-minute operation at rated capacity

Precision Measurement

Integrated HV voltage monitoring

Typical Applications

  • Low-frequency withstand voltage testing

  • Power transformer diagnostic tests

  • High-voltage cable aging studies

  • Industrial equipment insulation validation

Standards Compliance

  • IEC 60076 (Power Transformers)

  • IEEE C57.12.01 (General Requirements)

  • EN 60296 (Transformer Oil Standards)

Why Choose This Transformer?

  1. Unique Frequency Range: 20Hz capability for specialized testing

  2. Triple-Voltage Flexibility: 2.4kV to 4.8kV in one unit

  3. Industrial Durability: Continuous operation capability

  4. Measurement Ready: Built-in HV monitoring

Conclusion

The HET 400kVA/4.8kV Exciter Transformer combines rare low-frequency capability with high-current capac

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message