>400kVA Rang
HET 400kVA/30kV Exciter Transformer - Multi-Range Frequency-Variable Testing
The HET 400kVA/30kV,20kV,10kV,5kV Exciter Transformer provides unparalleled testing versatility with four independent HV outputs, wide frequency range (20-300Hz), and advanced electrostatic shielding for critical power equipment evaluation.
Technical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 400kVA |
Frequency Range | 20-300Hz |
HV Winding Voltage | 5kV, 10kV, 20kV, 30kV (Independent) |
HV Winding Current | 80A (5kV), 40A (10kV), 20A (20kV), 16.6A (30kV) |
LV Winding Voltage | 2×400V, 2×460V, 2×500V |
LV Winding Current | 2×434.8A |
No-Load Current | <8% |
Impedance Voltage | <6% |
Cooling Method | ONAN (Oil Natural Air Natural) |
Temperature Rise | Winding <65K, Oil <55K |
Noise Level | ≤60dB |
Advanced Design Features
Core & Winding Technology
Premium Core Material: D0130-30 cold-rolled silicon steel with ultra-low Bm value
Quad Independent Windings: Four separate HV coils for precise voltage selection
Electrostatic Shielding: Isolation filter between LV/HV windings prevents interference
Monitoring & Protection
Integrated Measurement: HV-side voltage measurement coil for precision monitoring
Oil Management System:
Expansion tank with moisture absorber
Temperature thermograph and level indicator
Structural Advantages
Shell-Type Construction: Oil-immersed design with transport-optimized components
Safety-Spaced Windings: Prevents partial discharge and corona effects
Copper Lead Wires: High-conductivity connections for 434.8A LV current
Performance Benefits
Wide Frequency Range
20-300Hz operation for specialized test protocols
Four Voltage Ranges
5kV to 30kV coverage in one unit
High Current Capacity
80A at 5kV for demanding test scenarios
Thermal Stability
ONAN cooling with 25# transformer oil
Industrial Applications
Frequency-dependent withstand voltage tests
Power transformer diagnostic testing
High-voltage cable partial discharge measurement
Research lab insulation aging studies
Standards Compliance
IEC 60076 (Power Transformers)
IEEE C57.12.90 (Test Code)
EN 60296 (Transformer Oil Standards)
Why Choose This Transformer?
Unmatched Flexibility: Combines 4 voltage ranges with wide frequency bandwidth
Measurement Precision: Integrated HV monitoring for accurate results
Industrial Durability: Designed for continuous operation
Future-Proof Design: Adaptable to evolving testing standards
Conclusion
The HET 400kVA/30kV Exciter Transformer represents the pinnacle of high-voltage testing technology, combining exceptional range flexibility with laboratory-grade precision for utility, manufacturing, and research applications.