High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

100kVA ~ 400kVA Range

HET 375kVA/37.5kV Exciter Transformer | Triple-Range HV Testing (12.5-37.5kV) with Ultra-Low Partial Discharge

The HET 375kVA/37.5kV Exciter Transformer delivers three voltage ranges (12.5-37.5kV) with ultra-low <2pC partial discharge at 80% load, electrostatic shielding, and military-grade protection for critical HV testing.


  • US$ 24,591.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

HET 375kVA/37.5kV Exciter Transformer - Precision High-Voltage Testing

The HET 375kVA/37.5kV,25kV,12.5kV Exciter Transformer redefines high-voltage testing standards with triple-range output, industry-leading partial discharge performance (<2pC at 80% load), and failsafe operator protection systems.

Technical Specifications

ParameterSpecification
Rated Capacity375kVA
PhaseSingle
Cooling MethodONAN (Oil Natural Air Natural)
LV Voltage Options0.35kV, 0.4kV, 0.45kV
HV Voltage Ranges12.5kV, 25kV, 37.5kV
LV Current937.5A
HV Currents30A (12.5kV), 15A (25kV), 10A (37.5kV)
Frequency50Hz
Impedance Voltage<4%
Partial Discharge<10pC (100% load), <2pC (80% load)

Cutting-Edge Design Features

Voltage & Insulation System

  • Triple-Range Output: 12.5kV to 37.5kV with precision taps

  • Electrostatic Shielding: Multi-layer isolation between HV windings

  • Ultra-Low Discharge: <2pC at 80% rated voltage (superior to IEC 60270 Class I)

Safety & Protection

  • Dual-Protection System:

    • Piezoresistor arrays on each HV output

    • Zinc oxide arresters (IEEE C62.11 compliant)

  • 40kV Corona-Free: Fiberglass bushings with triple corona rings

  • Flashover Prevention: Turn-to-turn insulation withstands 200% surges

Structural Engineering

  • Mobile Test Platform: Wheel-mounted steel enclosure (800×600×1200mm)

  • Advanced Bushings:

    • HV: Isovolumetric capacitance core (37.5kV rating)

    • LV: Porcelain bushings per IEC 60137

  • Oil Management: Conservator with temperature-compensated level indicator

Performance Advantages

Micro-Discharge

<2pC at 80% load ensures lab-grade accuracy

Triple-Range Flexibility

12.5kV-37.5kV coverage for diverse test scenarios

High Current Capacity

937.5A LV current for heavy-duty testing

Thermal Stability

ONAN cooling with 25# transformer oil

Industrial Applications

  • Power transformer factory acceptance tests

  • HV cable partial discharge measurement

  • GIS (Gas In

>>>WhatsApp Communication<<<