100kVA ~ 400kVA Range
HET 350kVA/4kV Exciter Transformer - High-Capacity Multi-Range Solution
The HET 350kVA/4kV,3.5kV,2.5kV,1.75kV Exciter Transformer provides laboratory-grade testing capabilities with four voltage outputs, industry-leading impedance performance (<3%), and robust protection systems for demanding industrial applications.
Technical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 350kVA |
Phase | Single |
Cooling Method | ONAN (Oil Natural Air Natural) |
LV Voltage | 0.4kV |
HV Voltage Ranges | 1.75kV, 2.5kV, 3.5kV, 4kV |
LV Current | 875A |
HV Currents | 200A (1.75kV), 100A (3.5kV), 87.5A (4kV) |
Frequency | 50Hz |
Impedance Voltage | <3% |
Advanced Design Features
Voltage & Insulation System
Quad-Range Precision: 1.75kV to 4kV outputs with identical current density
Electrostatic Shielding: Multi-layer isolation between HV windings
Cylinder Windings: Balanced top/bottom area with shield compensation
Safety & Protection
Dual-Protection Mechanism:
Piezoresistor arrays on each HV output
Zinc oxide arresters (IEEE C62.11 compliant)
5kV Corona-Free: Fiberglass bushings with integrated rings
Flashover Prevention: Turn-to-turn insulation withstands 150% surges
Structural Engineering
Mobile Test Platform: Wheel-mounted steel enclosure (900×600×1200mm)
Advanced Bushings:
HV: Isovolumetric capacitance core fiberglass
LV: Porcelain bushings per IEC 60137
Oil Management: Conservator with magnetic oil level indicator
Performance Advantages
Ultra-Low Impedance
<3% ensures minimal voltage regulation loss
High Current Capacity
875A LV current for heavy-duty applications
Multi-Test Flexibility
4 voltage ranges cover diverse testing needs
Enhanced Safety
Redundant protection systems meet IEC 60076
Industrial Applications
Industrial motor and generator testing
Power transformer routine maintenance
Medium-voltage cable factory tests
Research lab insulation studies
Certifications & Compliance
IEC 60076 (Power Transformers)
IEEE C57.12.00 (Safety Requirements)
EN 50588 (Partial Discharge Testing)
Why Choose This Model?
Exceptional Efficiency: <3% impedance maximizes power transfer
Test Versatility: Handles 1.75kV to 4kV requirements
Industrial Durability: Robust construction for harsh environments
Maintenance-Friendly: Wheeled design with visual indicators
Conclusion
The HET 350kVA/4kV Exciter Transformer sets new benchmarks for high-current, low-voltage testing, combining four precision ranges with military-grade protection systems for industrial and utility applications.