High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

100kVA ~ 400kVA Range

HET 350kVA/11.7kV Exciter Transformer | Dual-Range HV Testing (5.8kV-11.7kV) with <2pC Partial Discharge

The HET 350kVA/11.7kV Exciter Transformer delivers dual voltage outputs (5.8-11.7kV) with ultra-low <2pC partial discharge, electrostatic shielding, and failsafe operator protection for precision high-voltage testing.


  • US$ 21,804.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

HET 350kVA/11.7kV Exciter Transformer - Precision Dual-Range Testing

The HET 350kVA/11.7kV,5.8kV Exciter Transformer is engineered for laboratory-grade high-voltage testing, featuring dual-range outputs, industry-leading partial discharge performance (<2pC), and military-spec protection systems for critical power applications.

Technical Specifications

ParameterSpecification
Rated Capacity350kVA
PhaseSingle
Cooling MethodONAN (Oil Natural Air Natural)
LV Voltage6kV
HV Voltage Ranges5.8kV, 11.7kV
LV Current58.3A
HV Currents60A (5.8kV), 30A (11.7kV)
Frequency60Hz
Impedance Voltage<5%
Partial Discharge<2pC at rated voltage

Innovative Design Features

Voltage & Insulation System

  • Dual-Range Precision: 5.8kV and 11.7kV outputs with identical current density

  • Electrostatic Shielding: Multi-layer isolation between HV/LV windings

  • Cylinder Windings: Balanced top/bottom area with shield compensation

Safety & Protection

  • Piezoresistor Arrays: Each HV output protected against transient surges

  • Zinc Oxide Arresters: Grounded terminals meet IEEE C62.11 standards

  • 12kV Corona-Free: Fiberglass bushings with triple-ring design

Structural Engineering

  • Mobile Test Unit: Wheel-mounted steel enclosure with shell-type oil tank

  • Advanced Bushings:

    • HV: Isovolumetric capacitance core fiberglass

    • LV: Porcelain bushings by IEC 60137

  • Oil Management: Conservator with magnetic oil level indicator

Performance Advantages

Ultra-Low Discharge

<2pC ensures research-grade measurement accuracy

Dual-Range Efficiency

5.8kV/11.7kV switching without performance compromise

60Hz Optimization

Specialized for North American power standards

Flashover Prevention

Turn-to-turn insulation layers withstand 150% rated voltage

Industrial Applications

  • Medium-voltage cable factory testing

  • Power transformer routine tests

  • Industrial motor insulation diagnostics

  • University high-voltage labs

Certifications & Compliance

  • IEEE C57.12.90 (Test Code)

  • IEC 60076-3 (Insulation Levels