100kVA ~ 400kVA Range
HET 200kVA/20kV Exciter Transformer - Triple Voltage Output for High Frequency Testing
Technical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 200kVA |
Frequency Range | 25-300Hz |
Input Voltage | 2×300V / 2×350V / 2×400V |
Output Voltage | 4kV / 10kV / 20kV |
Output Current | 18A (4/10kV), 10A (20kV) |
Duty Cycle | 15min ON / 60min OFF (4 cycles/day) |
Key Features
Flexible Voltage Output
Three selectable output voltages
Wide frequency operation (25-300Hz)
Optimized for intermittent testing cycles
Electrostatic shielding between windings
Premium Construction
Oil-immersed shell-type design
D0130-30 high-grade silicon steel core
Double-coil copper wire windings
Integrated measuring coil for HV monitoring
Advanced Monitoring System
Oil expansion tank with moisture absorber
Temperature thermograph and level indicator
Transport-optimized component layout
Low noise operation (≤60dB)
Performance Parameters
Cooling: ONAN with 25# transformer oil
Temperature Limits: 65°C (windings), 55°C (oil)
Continuous Operation: 15 minutes at rated capacity
Impedance: ≤5%
Insulation System
LV winding withstand: 3kV/1min
HV winding withstand: 110% rated voltage for 60s
Ample HV/LV winding clearance
Corona-free design up to 20kV
Safety & Reliability
Class A heat resistance rating
Partial discharge prevention design
Isolation filter function
All bushings and valves transport-secured
Typical Applications
Variable frequency resonant testing
Cable and capacitor withstand tests
Medium-voltage equipment validation
Transformer factory acceptance testing
The HET 200kVA/20kV exciter transformer provides exceptional testing flexibility with its triple voltage outputs and wide frequency range, engineered for reliable performance in standardized testing cycles.