<1000kV Range
LQHID 300KV/400pF Weak Damping Capacitor Voltage Divider
Engineered for ultra-high-voltage applications, the LQHID 300KV/400pF Multistage Capacitor Divider delivers precision measurements up to 300kV. Featuring advanced corona prevention, distributed damping technology, and GB311 compliance, this robust solution is ideal for power transmission testing and high-voltage research.
Technical Specifications
Parameter | Specification |
---|---|
Model | LQHID 300KV-400pF |
HV Arm Configuration | Multistage pulse capacitors (series connection) |
Standard Lightning Wave | +300kV impulse withstand |
Rated Capacitance | 400pF ±5% |
Damping System | Multistage distributed resistors |
Partial Response Time (Tα) | ≤100 nanoseconds |
Overshoot (β) | ≤20% |
Scale Factor Uncertainty (Ks) | ±1% |
Standards Compliance | GB311 (square wave response 0-9.9μS) |
Top Electrode Material | Stainless steel tube (field-installable) |
Advanced Design Features
Multistage Capacitor System
Series-connected pulse capacitors with distributed damping resistors eliminate inductance for accurate high-frequency response at 300kV/400pF.
Corona Prevention System
Optimized corona cover profile prevents discharge during 300kV+ switching impulses
Stainless steel top electrode minimizes abnormal flashover
Electrostatic field management for clean waveform capture
Industrial Mobile Platform
Heavy-duty movable base includes:
Polyurethane wheels with locking braces (2000kg capacity)
High-strength steel construction for stability
Field-installable top electrode for transport efficiency
Performance Specifications
Characteristic | Performance |
---|---|
Low-Voltage Arm | Parallel non-inductive capacitors |
Frequency Response | DC to 10MHz |
Impulse Polarity | Positive (+300kV) |
Dielectric Strength | 450kV (150% overvoltage withstand) |
Standards Compliance
Full GB311 square wave response compliance (0-9.9μS)
Compatible with IEC 60060-1 impulse test standards
Designed for IEEE 4 switching surge measurements
Industrial Applications
Transmission Systems: 300kV lightning impulse tests on transformers
Renewable Energy: Wind turbine generator insulation validation
Substation Testing: GIS circuit breaker switching surge analysis
Research Labs: HVDC converter station transient studies
Mechanical Construction
Base dimensions: Custom high-strength steel platform
Electrode: Field-installable 304 stainless steel tube
Wheel system: 150mm polyurethane with dual braking
Corona cover: Optimized profile for 300kV positive impulses
Operational Safety
3-meter minimum clearance at 300kV operation
Automatic grounding system for capacitor banks
EMI-shielded low-voltage connections
Corona discharge < 5pC at 250kV
Calibration & Maintenance
Factory calibration certificate included
Annual dielectric verification at 350kV AC
Biannual damping resistor network inspection
5-year full system recertification cycle
Technical Advantages
400pF capacitance for superior signal integrity
Distributed damping for minimal waveform distortion
Field-deployable design with quick assembly
Advanced corona control for reliable 300kV measurements
Support Services
GB311 compliance documentation
On-site installation supervision
Custom calibration for specific test protocols
Lifetime technical consultation