High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

HVDC Test System

High-Voltage CT/PT | Metering & Protection Instrument Transformers | 69kV–800kV

IEC-compliant current & voltage transformers for substations. Includes metering CTs (0.2S), protection CTs (TPY), CVTs, and GIS-integrated PTs.


>>>WhatsApp Communication<<<

Product Details

Product Tags


Precision Instrument Transformers: CTs & PTs for Grid Monitoring & Protection

*IEC 61869 / IEEE C57.13 Compliant | 69kV–800kV | Metering & Protection Grades*


Core Functions

TypeFunctionCritical Applications
CT (Current Transformer)Steps down high current (kA) to standardized outputs (1A/5A)Relay protection, energy metering, fault recording
PT (Potential Transformer)Steps down high voltage (kV) to standardized outputs (110V/120V)Synchronization, voltage regulation, revenue metering

Technical Specifications

Current Transformers (CTs)

ParameterMetering CTProtection CTTransient Performance CT
Accuracy Class0.2S, 0.5S (IEC 61869-2)5P, 10P (IEC 60044-1)TPX, TPY (IEC 61869-6)
Burden≤5 VA15–30 VADynamic burden compensation
Rated Primary100A–6000A300A–63kAUp to 80kA (fault current)
Rated Short-Time Current-10–50 kA/1s or 3s63kA/120ms (C&O cycles)
Core MaterialNanocrystallineGrain-oriented silicon steelHybrid amorphous/silicon

Voltage Transformers (PTs)

TypeElectromagnetic PTCapacitive VT (CVT)GIS Integrated
Voltage Range72.5kV–245kV123kV–800kV72.5kV–550kV (SF6 insulated)
Accuracy Class0.1, 0.2 (IEC 61869-3)0.2, 0.50.2S
Frequency Range15–100Hz15–150Hz (harmonics)DC–500Hz
Dielectric MediumOil/SF6Oil-impregnated paperSF6 gas
Resonance ControlFerro-resonance suppressionDamping filtersActive electronic damping

Critical Design Features

CT Innovations

✅ Anti-Saturation Core Design

  • Transient-tolerant cores for fault currents >40kA

  • Remanence <10% (TPY class)
    ✅ Hybrid Insulation Systems

  • RIP (Resin-Impregnated Paper) for 245kV+

  • Silicone composite sheds for coastal pollution
    ✅ Optical Sensing Options

  • Rogowski coils (0.2% accuracy)

  • Faraday effect sensors (345kV+)

PT/CVT Advancements

✅ Zero-Ferroresonance Circuits

  • Active damping for grid switching transients
    ✅ HVDC-Ready CVTs

  • DC-bias tolerant up to ±1200kV
    ✅ Seismic Resilience

  • IEC 60255-21-3 compliance (Zone 4 seismic)


Application Matrix

Grid SegmentRecommended CTRecommended PTKey Standard
Distribution (≤36kV)Low-Burden 0.5S Metering CTsDry-Type Electromagnetic PTIEEE C57.13.6
Transmission (110–500kV)TPY Protection CTsCVT with Harmonics FilterIEC 61869-5
HVDC StationsOptical DCCTs (0.1%)Resistive DC DividersIEC 61869-11
RenewablesDual-core (Metering+Protection)Wideband RIP PTs (15–150Hz)IEC 60044-8

Compliance & Testing

  • Type Tests:
    • Power frequency withstand (IEC 60060-1)
    • Lightning impulse (1.2/50μs) & chopped wave
    • Temperature rise (IEC 60076-2)

  • Routine Tests:
    • Ratio/polarity verification
    • Burden accuracy validation
    • Partial discharge <5pC @ 1.2Ur