<1000kV Range
LQHID 300KV/500pF Weak Damping Capacitor Voltage Divider
Engineered for laboratory-grade precision in ultra-high-voltage applications, the LQHID 300KV/500pF Capacitor Divider delivers exceptional measurement accuracy with industry-leading<10% overshoot.="" featuring="" single-stage="" construction="">
Technical Specifications
Parameter | Specification |
---|---|
Rated Voltage | +300kV DC/Impulse |
Capacitance | 500pF ±5% |
Configuration | Single-stage weak damping |
Standards Compliance | IEC 60060-2 & GB/T 16927 |
Partial Response Time | <100 nanoseconds |
Overshoot | <10% |
Voltage Ratio | 1000:1 |
Ratio Instability | ≤1% |
Dimensions | 600mm × 600mm × 1800mm (L×W×H) |
Base Type | Mobile platform with locking system |
Performance Advantages
Superior Signal Integrity
500pF capacitance provides enhanced signal-to-noise ratio for accurate measurement of fast transients and low-magnitude waveforms.
Industry-Leading Response
<100ns partial response time
<10% overshoot - 50% better than standard dividers
Stable 1000:1 ratio with ≤1% uncertainty
Advanced Damping Technology
Integrated resistor-capacitor network minimizes waveform distortion during:
Lightning impulse tests (1.2/50μs)
Switching surge measurements
High-frequency transient capture
Standards Compliance
Standard | Requirement | Compliance |
---|---|---|
IEC 60060-2 | High-voltage test techniques | Full |
GB/T 16927 | HV testing standards | Certified |
Square Wave Response | Calibration coefficient | 0-9.9μS range |
Design Features
Robust Single-Stage Construction
Monolithic 300kV/500pF capacitor eliminates multi-stage distortion for cleaner signal output.
Mobile Operational Platform
Heavy-duty movable base with locking casters
Grounding points for safety compliance
Compact 600×600mm footprint for lab efficiency
Optimized Electrical Characteristics
Frequency response: DC to 15MHz
Dielectric strength: 450kV (150% overvoltage)
EMI-shielded low-voltage connections
Industrial Applications
Transformer Testing: 300kV lightning impulse withstand tests
Cable Diagnostics: Partial discharge detection in HV transmission lines
Switchgear Validation: Switching surge measurement in GIS
Research Labs: Transient overvoltage studies in HVDC systems
Renewable Energy: Wind turbine generator insulation validation
Operational Benefits
Feature | User Advantage |
---|---|
500pF Capacitance | Superior signal integrity in noisy environments |
<10% Overshoot | More accurate waveform reproduction |
Mobile Base | Easy repositioning in test labs |
Single-Stage Design | Reduced calibration complexity |
Calibration & Maintenance
Factory calibration certificate included
Annual dielectric verification at 350kV AC
Biannual ratio accuracy verification
Environmental tolerance: -25°C to +55°C
Humidity range: ≤95% non-condensing
Why Choose This Model?
The LQHID 300KV/500pF provides unmatched performance for critical high-voltage applications:
Industry-best <10% overshoot for precise measurements
High 500pF capacitance improves signal fidelity
Full compliance with international standards
Compact footprint saves valuable lab space
Mobile design enhances testing flexibility
Technical Support Services
IEC 60060-2 compliance documentation
On-site calibration service packages
Application-specific setup guidance
Integration support with major oscilloscope brands