≤100kV Range
Core Technical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 15 kVA |
Rated Output Voltage | 75 kV AC |
Rated Output Current | 0.2 A |
Input Voltage | 0.38 kV (380V) standard Customizable to local power standards |
Frequency | 50 Hz |
Impedance Voltage | ≤10% |
Premium Performance Metrics
Partial Discharge Level: <3 pC at 100% UH (full system verification)
Waveform Distortion: ≤5% (per IEC 60060-1)
No-load Current: ≤10%
Insulation Strength: 3kV/1min withstand (LV terminals to ground)
Advanced Operational Capabilities
Overcurrent Withstand: 150% rated current (0.3A) for 300s – zero damage to windings or insulation
Overvoltage Capability: 110% rated voltage (82.5kV) for 60s – guaranteed insulation integrity
Thermal Management:
60 minutes continuous operation at 100% rated voltage
Unlimited operation at 80% rated voltage/current
Winding temperature rise ≤65K
Oil surface temperature rise ≤55K
Design & Safety Features
Cooling System: ONAN (Oil Natural Air Natural)
Construction: Industrial-grade cylindrical tank
Phase Configuration: Single phase
Safety Compliance: Designed for operator protection during high-voltage testing