High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

≤100kV Range

LQTT 50kV/10kVA Ultra-HV Test Transformer

Portable 50kV/10kVA test transformer: <5pC PD, 40kg ultra-lightweight, ONAN cooling. Ideal for cable/bushing tests. Duty-cycle optimized operation.


  • US$ 3,254.00
  • Lead time: 45 days

>>>WhatsApp Communication<<<

Product Details

Product Tags


Technical Specifications

ParameterSpecification
Output Voltage50 kV
Rated Capacity10 kVA
Output Current0.2 A
Partial Discharge (PD)<5 pC at 100% U<sub>H</sub>
Waveform Deviation≤5%
No-Load Current≤10%
Impedance Voltage≤5%
Thermal LimitsWinding: ≤65K
Oil: ≤55K
DimensionsØ200/250 × 500 mm (Cylinder)
Weight<40 kg (Industry Lightest)
CoolingONAN (Oil Natural Air Natural)
Insulation3 kV/min (LV to Ground)

Key Innovations

✅ Ultra-Portable 50kV Solution
Industry's lightest 50kV transformer (40kg) with compact Ø250mm footprint

✅ Precision Diagnostics
<5pC PD sensitivity for critical insulation assessments (IEC 60270 compliant)

✅ Optimized Duty Cycling

Operational Cycling:
► 60 min at 100% load
► 60 min cooling rest
► Repeat 4× daily

✅ Enhanced Waveform Integrity
≤5% deviation meets IEC 60060-1 standards

✅ Efficient Cooling
ONAN system maintains safe operating temps:

  • Max oil rise: 55K

  • Max winding rise: 65K


Critical Applications

  • Cable Termination Testing (33-66kV class)

  • Bushing & Insulator withstand tests

  • GIS Partial Discharge measurement

  • Surge Arster validation

  • Transformer HV commissioning

  • Research Lab insulation studies


Operational Advantages

1. Duty-Cycle Engineered Reliability

  • Controlled thermal recovery during rest periods

  • Sustained 4-cycle daily operation

2. Safety by Design

  • Low impedance voltage (≤5%) reduces fault risks

  • 3kV/min LV-ground insulation protection


Technical Comparison

ModelVoltageWeightKey Advantage
LQTT-50/1050kV40kgUltra-portable 50kV
LQTT-50/750kV65kgHigher PD sensitivity
LQTT-30/1530kV50kgBalanced power/size

Why Engineers Specify This Model

"The LQTT-50/10 solves a critical challenge: bringing lab-grade 50kV testing to field sites. Its 40kg weight and duty-cycle design enable:

  • Mountain-top substation commissioning

  • Offshore platform cable tests

  • Mobile laboratory operations
    Where traditional HV test sets are logistically impossible."
    – Field Engineering Team


Ordering Details

Model: LQTT-50/10-CYL
Certification: IEC 60270, IEC 60060
Lead Time: 45 days

Options:

  • 60Hz frequency operation

  • NIST-traceable calibration certificate

  • Custom HV connectors (e.g., TNC, SHV)

  • Weatherproof transit case


>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message