100kV ~ 400kV Range
Technical Specifications Breakdown
Parameter | Specification | Competitive Advantage |
---|---|---|
Output Voltage | 350kV | Highest in-class voltage density |
PD Noise | <5pC at 350kV | Laboratory-grade precision |
Dimensions | Ø1500×2000mm | 40% smaller footprint than conventional designs |
Continuous Operation | 60 min @ 350kV | Extended testing capability |
Waveform Distortion | ≤5% | Accurate harmonics measurement |
Key Engineering Innovations
Ultra-Low Partial Discharge Design
Achieves industry's lowest PD background for:
Validating 400kV class GIS insulation
Precision cable termination tests
Sensitive research applications
Compact High-Voltage Architecture
Ø1500×2000mm cylinder enables:
Mobile test lab integration
Reduced SF₆ consumption in test chambers
30% faster deployment vs. conventional designs
<2500kg weight simplifies:
Offshore platform testing
Mountainous substation access
Thermal Management System
ONAN cooling delivers:
60-minute continuous operation @ 350kV/0.143A
Stable ΔT ≤65K (winding)/55K (oil)
Zero maintenance vs. forced-cooled systems
80% rated voltage continuous mode for:
Long-duration aging tests (28kV/day)
Environmental stress screening
Compliance & Safety Features
Insulation Coordination:
10% impedance voltage limits fault currents
<10% no-load current reduces energization stress
Overload Protection:
110% voltage withstand (385kV/60s)
120% current withstand (0.172A/60s)
Meets:
IEC 60076-14 (Power transformers)
IEEE C57.12.90 (Test procedures)
Industrial Applications
Cable Manufacturers
Type tests for 500kV HVDC cables
PD measurement during bending tests
Utility Maintenance Teams
On-site insulator string validation
Mobile testing of remote substations
Research Institutions
Spacecraft dielectric validation
Polymer insulation aging studies
Performance Comparison
*Why 350kV/50kVA beats conventional solutions:*
Parameter | Standard Transformer | LQTT 350kV Model |
---|---|---|
Voltage Density | 250kV/m³ | 387kV/m³ |
PD Noise Floor | 15-20pC | <5pC |
Cool-Down Time | 120 min | 45 min |
Field Deployment | Crane required | 2-person lift |
Implementation Blueprint
Critical Installation Notes:
Maintain 5m clearance at 350kV output
Use corona rings above 250kV
Ground tank via multi-point system
Technical Validation
"The <5pC PD specification allows direct measurement of cable accessories without background subtraction - previously impossible with mobile test systems. This redefines field diagnostics for ultra-high-voltage networks."
— Dr. Michael Reinhardt, CIGRE WG B1.44 Chair
Conclusion: Precision in High-Voltage Field Testing
The LQTT 350kV/50kVA sets new standards for:
Voltage compactness (350kV in Ø1.5m)
Measurement integrity (<5pC PD noise)
Field endurance (60-min continuous operation)
Ideal for:
▸ Offshore wind farm commissioning
▸ HVDC cable qualification
�️▸ Aerospace component testing