High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

100kV ~ 400kV Range

LQTT 270kV/54kVA HV Test Transformer | <3pC PD | IEC-Compliant

54kVA test transformer with 270kV output & <3pC PD sensitivity at 216kV. ONAN cooling, 60-min peak operation. Technical specs & datasheet.


  • US$ 19,108.00
  • Lead time: 60 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQTT Series 270kV/54kVA High-Voltage Test Transformer

(Cylinder Type | Single Phase | Precision PD Testing)

Key Performance Advantages

✅ Enhanced Voltage Output: 270kV Rating (7%↑ vs. industry-standard 250kV units)
✅ Advanced PD Sensitivity:

  • <5pC @ 100% Uₕ (270kV)

  • <3pC @ 80% Uₕ (216kV) - Best-in-class for diagnostic testing
    ✅ Optimized Power Density: 54kVA Capacity at <1500kg (35% lighter than comparable units)
    ✅ Robust Thermal Management: ONAN cooling with validated thermal limits


Technical Specifications

ParameterValueStandard
Electrical

Frequency50 HzIEC 60076
Input Voltage0.4 kV
Input Current135 A
Output Voltage270 kV*(Calculated: 54kVA/0.2A)*
Output Current0.2 A
No-Load Current<10%IEEE C57.12.00
Waveform Distortion≤5%IEC 60060-1
Impedance Voltage≤10%IEC 60076-1
Thermal

Winding Temp Rise≤65 K (80% continuous)IEC 60076-14
Oil Surface Temp Rise≤55 K (80% continuous)IEC 60076-14
Duty Cycle

Peak Operation60 min @ 270kV/0.2A
Continuous OperationUnlimited @ 216kV/0.16A
Mechanical

DimensionsØ1200 × 2300 mm(Corrected notation)
Weight<1500 kgISO 9001

Engineering Innovations

  1. Voltage-Scaled PD Performance


    100% Uₕ (270kV): <5pC → Production-line testing  
    80% Uₕ (216kV): <3pC → Critical defect identification

    Exceeds IEC 60270 Class II requirements for switchgear validation

  2. Compact High-Voltage Design

    • Ø1200mm cylinder tank with optimized core geometry

    • 2300mm height enables standard lab installation

    • Power-to-weight ratio: 36 VA/kg (industry average: 25 VA/kg)

  3. Stable Power Delivery


    Continuous 80% load (43.2kVA):  
    - Winding ΔT ≤65K  
    - Oil ΔT ≤55K
    • ≤10% impedance ensures <2% voltage drop at full load

    • ONAN cooling maintains thermal safety margins:


Target Applications

  • GIS Partial Discharge Mapping (IEC 62271-203)

  • 270kV Cable Qualification Testing (IEC 60840/62067)

  • Transformer Impulse Testing with cascaded units

  • HVDC Component Validation


Competitive Advantages

► Diagnostic Precision: <3pC sensitivity at 216kV enables micro-defect detection
► Future-Proof Voltage: 270kV headroom for next-gen 245kV equipment testing
► Portability: Forklift pockets & lifting lugs for field deployment
► Compliance: Meets CE (EN 50588), UKCA (BS EN 60076), and CNAS (GB/T 16927)


>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message