High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

150kV ~ 400kV

LQHDR 350kV/5kΩ/0.714A High Voltage Damping Resistor | 2.55kW Precision Design

Precision LQHDR 350kV/5kΩ/0.714A damping resistor with 2.55kW rating. Features <2pC partial discharge, 100K max temperature rise, and 60min continuous operation at full load.


  • US$ 2,733.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHDR Series 350kV/5kΩ/0.714A High Voltage Damping Resistor

Technical Specifications

ParameterValueVerification
Rated Voltage350kV AC RMSIEC 60060-1
Nominal Resistance5kΩ ±2%IEC 60115-1
Rated Current0.714A continuous
Power Rating2.55kW @ 50HzP = I2R = (0.714)2 × 5000 = 2.55kW
Duty Cycle60min ON / 45min OFF
Temperature Rise≤100K at full loadIEC 60076-7
Partial Discharge<2pC @ 350kVIEC 60270
Voltage Coefficient<0.008%/kV
BIL Rating525kVIEC 60071

Thermal Management System

Advanced Cooling Design

  • Helical aluminum fins (12mm pitch)

  • Vertical airflow channels

  • Black anodized surface (ε=0.85 emissivity)

Temperature Performance

  • 100K max rise at 2.55kW load

  • Thermal time constant: 18 minutes

  • Ambient range: -30°C to +50°C

Thermal Validation: Tested per IEEE C57.131 with IR thermography

Electrical Performance

CharacteristicValue
TCR (Temp Coefficient)±200 ppm/°C (-40°C to +125°C)
Inductance<7μH
Step Response<30ns 10-90% rise time
di/dt Capability>3×109 A/s
Overload Capacity120% for 10min (3.06kW)

Mechanical Design

Dimensions & Construction

  • Cylindrical form factor

  • Stainless steel core

  • Aluminum oxide coated surface

Terminal System

  • Top: Corona shield (Ø500mm)

  • Base: M20 flange terminals

  • Torque spec: 40Nm ±5%

Primary Applications

High Power Laboratories

Critical component in 350kV impulse generators (0.84/2100μs switching surge)

Transformer Testing

Damping for resonant frequency tests on 500MVA+ transformers

HVDC Systems

Surge protection in ±350kV converter stations and VSC installations

Installation Protocol

  1. Maintain 2.45m clearance (7mm/kV × 350kV) to earthed surfaces

  2. Mount on insulated pedestal (≥200kV rating)

  3. Apply UV-resistant silicone grease to terminals

  4. Ground connection: ≥25mm² copper cable to

    <5ω earth="">
  5. Verify vertical alignment with

    <1° deviation="">

Safety & Compliance

  • Dielectric test: 420kV AC for 1min (20% overvoltage)

  • Short-circuit withstand: 12kA peak/80ms

  • Arc-flash protection: Grade 2 containment

  • Environmental rating: IP54 (indoor/outdoor)

  • Seismic rating: IEC 60068-3-3 Class 1

Operational Limits

ParameterOperating Range
Ambient Temperature-30°C to +50°C
Relative Humidity<95% non-condensing="">
Altitude<2500m asl="">
Cooling Recovery60min after full-duty cycle

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message