150kV ~ 400kV
LQHDR Series 270kV/2kΩ High-Current Damping Resistor
Technical Specifications
Rated Voltage: 270kV AC (50/60Hz)
Nominal Resistance: 2kΩ ±2%
Rated Current: 1.5A continuous
Power Rating: 405kW peak (270kV × 1.5A)
Partial Discharge (PD):
<2pC at 270kV (100% rated voltage)
<1pC at 235kV (87% rated voltage)
Operating Duration: 30 minutes at 270kV/1.5A continuous load
Thermal Design: Forced-air cooling required for full power operation
Compliance Standards: IEC 60270:2015 (PD), IEC 60060-1:2010 (HV testing)
Key Performance Advantages
High Current Capability: 1.5A rating for power system testing
Ultra-Low PD Performance: Industry-leading discharge levels for sensitive measurements
Robust Thermal Management: Dual-path cooling channels integrated in core design
Precision Resistance: ±2% tolerance across full operational range
High di/dt Handling: Stable performance under rapid current transients
Application Scenarios
Application | System Voltage | Performance Benefit |
---|---|---|
Circuit Breaker Testing | 245kV+ systems | High-current arc suppression |
Transformer Impulse Testing | 150-300kV range | Precise waveform control |
HVDC Converter Stations | ±250kV DC systems | DC partial discharge limitation |
High-Power Research | Plasma/accelerator systems | Stable load at extreme parameters |
Cooling System Requirements
Mandatory cooling configuration for full-power operation:
Airflow: Minimum 200 CFM axial flow
Ducting: 300mm diameter aluminum ducts
Temperature Monitoring: Integrated Type K thermocouples
Safety Interlock: Automatic shutdown at 120°C core temperature
Design Note: The LQHDR-270/2K utilizes proprietary helical fin design that increases heat transfer surface by 300% compared to conventional resistors.
Installation Specifications
Mounting: Vertical orientation recommended
Clearances:
2.5m phase-to-phase minimum
3.0m to grounded structures
Connections: Water-cooled terminals (M30 flange)
Environmental: IP55 rated enclosure
Altitude: Derate 1% per 100m above 1000m ASL
Safety & Compliance
IEC 61010-1:2010 CAT IV 300kV certification
Partial discharge verified per IEC 60270 Class I
Short-circuit withstand: 25kA/100ms
Dielectric strength: 350kV AC for 1 minute
Fire resistance: UL94 V-0 rated materials
Operational Protocol
Pre-cooling: Initiate airflow 5 minutes before energization
Ramp-up: Increase voltage at ≤5kV/s rate
Continuous Monitoring: Core temperature, airflow velocity
Cooldown: Maintain airflow for 10 minutes post-operation
Maintenance: Quarterly insulation resistance check (≥10GΩ)