LQTT 250kV/15kVA HV Test Transformer | <2pC PD | IEC-Compliant

15kVA test transformer with industry-leading <2pC partial discharge sensitivity. 50Hz design, ONAN cooling, 80% continuous duty cycle. Technical specs & datasheet.


  • US$12510.00
  • Lead time: 45 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQTT Series 250kV/15kVA High-Voltage Test Transformer

(Cylinder Type | Single Phase | IEC-Compliant)

Key Performance Highlights

✅ Ultra-Low Partial Discharge: <2pC at 100% Uₕ (Industry-leading sensitivity)
✅ Enhanced Capacity: 15kVA Output (+50% power vs. standard 10kVA models)
✅ Robust Thermal Design:

  • Continuous operation at 80% rated load (12kVA)

  • Intermittent duty: 1hr ON/OFF at 100% load
    ✅ Precision Waveform: ≤5% THD (IEC 60270 compliant)


Technical Specifications

ParameterSpecificationStandard
Frequency50 HzIEC 60076
Input Voltage0.4 kV
Output Voltage250 kV
Input Current37.5 A
Output Current0.06 A
No-Load Current<10%IEEE C57.12.00
Impedance Voltage≤10%IEC 60076-1
Temperature Rise (Wdg)≤65 K (80% continuous)IEC 60076-14
Temperature Rise (Oil)≤55 K (80% continuous)IEC 60076-14
Cooling MethodONAN (Oil Natural Air Natural)ISO 2206

Engineering Advantages

  1. PD Performance Benchmark

    • GIS systems

    • XLPE cables

    • Transformer bushings

    • <2pC sensitivity enables detection of microscopic insulation defects in:

    • Exceeds IEEE 1799 recommendations for diagnostic testing

  2. Thermal Reliability

    • Validated thermal limits (65K winding / 55K oil rise):

            Continuous Operation: 12kVA (80% load)  

            Cyclic Peak: 15kVA (1hr intervals)

   3.Frequency Optimization

    • 50Hz design tailored for EU/APAC markets (EN 50178 compliance)

    4.Zero-Compromise Safety

    • Built-in impedance protection against flashover

    • Short-circuit withstand per IEC 61378-1


Target Applications

  • Partial Discharge Calibration (IEC 60270)

  • Type Tests for HV cables & switchgear

  • Routine Testing of transformers ≥245kV class

  • Research Labs (dielectric strength validation)


Why This Transformer?

► Higher Efficiency: 15kVA capacity reduces testing time by 33% vs. 10kVA units
► Future-Proof: Supports 420kV DC tests with cascading configuration
► Critical Infrastructure Ready: Meets BSI/NFPA 70E safety requirements