High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

150kV ~ 400kV

LQHDR 250kV/10kΩ/0.08A Damping Resistor | High-Voltage Testing | 60-Min Continuous Operation

Industrial-grade LQHDR 250kV damping resistor with 10kΩ resistance and 0.08A rating. Designed for 60-minute continuous operation in demanding high-voltage testing applications.


  • Negotiated Price
  • Lead time: 30days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHDR 250kV/10kΩ/0.08A Damping Resistor: High-Voltage Testing Performance

Precision Damping for Critical HV Applications

The LQHDR 250kV/10kΩ damping resistor delivers reliable oscillation suppression in high-voltage testing circuits up to 250kV. Engineered for 50Hz systems at 0.08A current, this specialized component ensures measurement accuracy during extended test cycles. With its certified 60-minute continuous operation at full load, it's essential for transformer impulse testing, cable diagnostics, and high-voltage research requiring stable performance under demanding conditions.

Technical Specifications

ParameterSpecification
ModelLQHDR 250kV/10kΩ/0.08A
Rated Frequency50Hz
Rated Voltage250kV
Rated Current0.08A
Nominal Resistance10kΩ ±1%
Calculated Power Rating64W (P = I²R = 0.08² × 10000)
Operating Time60 minutes continuous at 100% load
Compliance StandardsIEC 60060-1, IEEE 4

Performance Advantages

High-Voltage Stability

Specialized construction for 250kV systems with corona-free design. Voltage grading technology prevents surface tracking, ensuring reliable operation in humid environments.

Extended Operation Capability

Certified for continuous 60-minute operation at full 250kV/0.08A load - 35% longer duty cycle than standard HV resistors. Proprietary cooling design maintains stable resistance throughout test cycles.

Precision Damping Characteristics

Optimized 10kΩ resistance provides critical damping for:

  • Lightning impulse wave shaping (1.2/50μs)

  • Switching surge suppression (250/2500μs)

  • Partial discharge measurement circuits

Industrial Applications

IndustryApplicationBenefit
Power UtilitiesTransformer impulse testingWaveform control per IEC 60076-3
Cable ManufacturersHV cable partial discharge testingMeasurement stability for IEC 60502 compliance
Research FacilitiesDielectric strength experimentsExtended test duration capability
High-Voltage LabsCircuit breaker testingSurge suppression for accurate timing measurements

Installation & Safety

Mounting Requirements

  • Minimum clearance: 2.0m to grounded surfaces

  • Vertical orientation recommended (HV terminal upward)

  • Grounding: 16mm² copper minimum with secure bonding

Operational Protocols

  • Pre-heat at 10% voltage for 10 minutes before full-load tests

  • Monitor surface temperature with IR thermometer during operation

  • Allow 90-minute cooldown between test cycles

Safety Compliance: Meets IEC 61010-1 requirements for HV test equipment.

Technical Comparison

FeatureStandard 250kV ResistorLQHDR 250kV/10kΩ
Continuous Operation30-45 minutes60 minutes
Current Range0.1A minimum0.08A precision rating
Resistance Tolerance±5%±1%
Waveform ControlBasic dampingPrecision impulse shaping

Maintenance Protocol

  • Monthly Inspection: Visual check for surface contamination

  • Quarterly Testing:

    • Resistance verification (±1% tolerance)

    • Insulation resistance test (≥1GΩ at 5kV DC)

  • Annual Recalibration: Traceable to NIST standards

  • Lifetime: 10,000 operational hours with proper maintenance

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message