100kV ~ 400kV Range
LQTT Series 220kV/10kVA High Voltage Test Transformer
Engineered for ultra-high-voltage precision testing, this cylinder-type transformer delivers exceptional stability at 220kV with robust overload protection. Certified for critical applications requiring uncompromised accuracy in partial discharge (PD) measurement and dielectric validation.
Core Technical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 10 kVA |
Input Voltage | 0.4 kV AC |
Output Voltage | 220 kV AC |
Output Current | 0.045 A |
Input Current | 25 A |
Frequency | 50 Hz |
Cooling Method | ONAN (Oil-Natural Air-Natural) |
Waveform Distortion | ≤ 5% |
Impedance Voltage | ≤ 10% |
No-Load Current | ≤ 10% |
Dimensions | Cylinder type (Standard footprint) |
Weight | Optimized for lab mobility |
Performance Engineering Highlights
1. Robust Overload Protection
2. Thermal Resilience
Full Load Operation: 30 minutes at 220kV/0.045A
Continuous Duty: Unlimited operation at 176kV/0.036A (80% rating)
Strict Temperature Control:
Winding rise: ≤65K
Oil surface rise: ≤55K
3. Precision Voltage Generation
Clean Waveform (≤5% THD): Critical for harmonic-sensitive tests
Low Impedance (≤10%): Minimizes voltage drop under load
ONAN Cooling: Silent operation (<60dB) for lab environments
Certified Safety Systems
Insulation Integrity:
Withstands 3kV/min (LV input to ground) per IEC 61144Multi-Layer Protection:
Automatic thermal monitoring
Overload cut-off circuitry
Reinforced inter-winding isolation
Technical Validation
Test | Standard | Performance |
---|---|---|
Partial Discharge | IEC 60270 | System PD <2 pC* |
Dielectric Withstand | IEC 60060-1 | 220kV + 10% safety margin |
Temperature Rise | IEEE C57.12.90 | Verified ≤65K winding |
Typical performance in full test system |
Critical Applications
Ultra-HV Calibration: Reference source for 200kV+ measurement systems
Bushing/Cable Testing: Acceptance tests per IEC 60885/IEC 60137
Partial Discharge Research: Sensitive detection system validation
High-Altitude Simulation: Equipment testing for aviation/power transmission
Series Comparison
Model | Voltage | Key Advantage | Ideal Use Case |
---|---|---|---|
220kV/10kVA | 220kV | Industry-leading voltage | Aerospace/transmission R&D |
200kV/10kVA | 200kV | Precision PD (<1pC) | Calibration labs |
200kV/100kVA | 200kV | Industrial endurance (100kVA) | Cable factory testing |
150kV/350kVA | 150kV | High-current (4.8A) | Transformer manufacturing |
Why This Transformer?
Highest Standard Voltage: 220kV output for cutting-edge research
Precision Overload Tolerance: 150% current handling for fault simulation
Lab-Optimized Design: Compact footprint and silent operation
Global Compliance: Meets IEC/IEEE standards for export markets