100kV ~ 400kV Range
LQTT Series 200kV/50kVA High Voltage Test Transformer
Engineered for industrial high-current testing applications, this cylinder-type transformer delivers robust 50kVA capacity with precision partial discharge performance. Ideal for extended dielectric tests on cables, switchgear, and large transformers.
Key Specifications
| Parameter | Specification | |
|---|---|---|
| Rated Capacity | 50 kVA | |
| Input Voltage | 0.4 kV AC | |
| Output Voltage | 200 kV AC | |
| Output Current | 0.25 A | |
| Input Current | 125 A | |
| Frequency | 50 Hz | |
| Cooling Method | ONAN (Oil-Natural Air-Natural) | |
| Partial Discharge (PD) | <5 pC at 100% UH | (Full test system) |
| Waveform Distortion | ≤ 5% | |
| Impedance Voltage | ≤ 10% | |
| No-Load Current | ≤ 10% | |
| Dimensions | Ø1300 × 1600 mm (Dia. × H) | |
| Weight | < 1500 kg |
Performance Highlights
1. Industrial-Grade Power Handling

2. Thermal Resilience & Duty Cycles
Full Load Operation: 60 minutes at 200kV/0.25A
Continuous Duty: Unlimited operation at 160kV/0.2A (80% rating)
Temperature Limits:
Winding rise: ≤65K
Oil surface rise: ≤55K
3. Precision Engineering
Ultra-Low PD (<5pC): Meets IEC 60270 requirements for factory acceptance testing
Clean Waveform (≤5% THD): Ensures accurate harmonic-sensitive tests
Compact Footprint: Ø1300mm design optimizes lab space
Technical Validation
| Test | Standard | Performance |
|---|---|---|
| Dielectric Withstand | IEC 60060-1 | 200kV + 10% margin |
| Partial Discharge | IEC 60270 | <5pC @ 200kV |
| Temperature Rise | IEEE C57.12.90 | Winding: 65K max |
| Impedance Voltage | IEC 60076-1 | ≤10% at 50kVA |
Target Applications
Cable Qualification Testing: Extended duration withstand tests (IEC 60502)
Transformer Hipot Testing: Power frequency voltage tests (IEEE C57.12.90)
Switchgear Commissioning: GIS and breaker validation
High-Current PD Studies: Material research under sustained loads
Comparative Advantage
| Model | Capacity | Output Current | Key Strength |
|---|---|---|---|
| 200kV/50kVA | 50kVA | 0.25A | Industrial endurance |
| 200kV/20kVA | 20kVA | 0.1A | Overload protection |
| 200kV/10kVA | 10kVA | 0.05A | Precision PD (<1pC) |
| 150kV/350kVA | 350kVA | 4.8A | High-current testing |
Why This Transformer?
Highest 200kV Capacity: 2.5× more current than 20kVA model
Optimized Cooling: ONAN design eliminates fans/pumps
Space-Efficient: 1600mm height fits standard lab ceilings
IEC-Ready: Pre-configured for compliance testing
Call to Action
For high-power testing requirements:
⚡ [Download 50kVA Application Notes]
🔍 [Request Custom Configuration]
📞 [Schedule Factory Acceptance Demo]










