100kV ~ 400kV Range
LQTT Series 200kV/100kVA High Voltage Test Transformer
Engineered for industrial high-power testing, this cylinder-type transformer delivers unmatched 100kVA capacity with precision overload protection. Designed for critical applications requiring extended operation under extreme loads.
Core Technical Specifications
| Parameter | Specification |
|---|---|
| Rated Capacity | 100 kVA |
| Input Voltage | 0.6 kV AC |
| Output Voltage | 200 kV AC |
| Output Current | 0.5 A |
| Input Current | 166.6 A |
| Frequency | 60 Hz |
| Waveform Distortion | ≤ 3% |
| No-Load Current | ≤ 8% |
| Impedance Voltage | ≤ 8% |
| Noise Level | ≤ 60 dB |
| Dimensions | Ø1300 × 2000 mm (Dia. × H) |
| Weight | 2000 kg |
Performance & Safety Engineering
1. Robust Overload Capability

2. Advanced Insulation System
Winding Insulation Resistance:
HV/LV/Measurement windings: >1500 MΩ (mutual isolation)
Transformer Oil Specifications:
Property Value Standard Breakdown Voltage >60 kV/2.5mm IEC 60156 Moisture Content <15 ppm IEC 60814 Dielectric Loss <0.2% @ 25°C IEC 60247 Solidifying Point < -40°C ASTM D97 Acetylene-Free Confirmed IEC 60599
3. Thermal Resilience
Full Load Operation: 60 minutes at 200kV/0.5A
Continuous Duty: 80% rating (160kV/0.4A)
Temperature Rise Limits:
Winding: ≤65K
Oil Surface: ≤55K
Certified Protection Systems
Integrated Surge Arrestors:
0.6kV protection on excitation/transfer windings (IEEE C62.11 compliant)Multi-Barrier Safety:
Triple-winding isolation (>1500 MΩ)
Oil dielectric stability (IEC 60296 standards)
Technical Validation Table
| Test | Standard | Performance |
|---|---|---|
| Partial Discharge | IEC 60270 | System PD <5 pC |
| Temperature Rise | IEEE C57.12.90 | Verified ≤65K winding |
| Impedance Voltage | IEC 60076-1 | ≤8% at 100kVA |
| Insulation Resistance | IEC 60060-3 | >1500 MΩ all paths |
Industrial Applications
Cable Factory Acceptance: Extended 60-min tests per IEC 60502
Power Transformer Hipot: Commissioning tests (IEEE C57.12.00)
GIS Switchgear Validation: Sustained voltage application
High-Capacity Research: Material breakdown studies at industrial scale
Series Comparison
| Model | Capacity | Key Advantage | Target Use Case |
|---|---|---|---|
| 200kV/100kVA | 100kVA | Industrial endurance | Cable/transformer factories |
| 200kV/50kVA | 50kVA | Balanced power/size | Medium-scale testing |
| 200kV/20kVA | 20kVA | Precision PD control | Calibration labs |
| 150kV/350kVA | 350kVA | Ultra-high current (4.8A) | Short-circuit testing |
Why This Transformer?
Highest 200kV Capacity: 2× more power than 50kVA model
Industrial Overload: 130% current handling for fault simulation
Silent Operation: ≤60dB for plant-floor environments
Oil Quality Assurance: #25 Chinese oil meets IEC 60296