High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

100kV ~ 400kV Range

LQTT 200kV/100kVA Industrial Test Transformer | 130% Overload | ≤60dB Noise | IEC-Compliant

Heavy-duty 100kVA HV transformer: 200kV output, 130% overload capacity, <60dB noise. Ideal for extended cable/transformer testing with full IEC compliance.


  • US$ 15,927.00
  • Lead time: 50 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQTT Series 200kV/100kVA High Voltage Test Transformer

Engineered for industrial high-power testing, this cylinder-type transformer delivers unmatched 100kVA capacity with precision overload protection. Designed for critical applications requiring extended operation under extreme loads.

Core Technical Specifications

ParameterSpecification
Rated Capacity100 kVA
Input Voltage0.6 kV AC
Output Voltage200 kV AC
Output Current0.5 A
Input Current166.6 A
Frequency60 Hz
Waveform Distortion≤ 3%
No-Load Current≤ 8%
Impedance Voltage≤ 8%
Noise Level≤ 60 dB
DimensionsØ1300 × 2000 mm (Dia. × H)
Weight2000 kg

Performance & Safety Engineering

1. Robust Overload Capability

deepseek_mermaid_20250607_d1f480.png

2. Advanced Insulation System

  • Winding Insulation Resistance:

    • HV/LV/Measurement windings: >1500 MΩ (mutual isolation)

  • Transformer Oil Specifications:

    PropertyValueStandard
    Breakdown Voltage>60 kV/2.5mmIEC 60156
    Moisture Content<15 ppmIEC 60814
    Dielectric Loss<0.2% @ 25°CIEC 60247
    Solidifying Point< -40°CASTM D97
    Acetylene-FreeConfirmedIEC 60599

3. Thermal Resilience

  • Full Load Operation: 60 minutes at 200kV/0.5A

  • Continuous Duty: 80% rating (160kV/0.4A)

  • Temperature Rise Limits:

    • Winding: ≤65K

    • Oil Surface: ≤55K


Certified Protection Systems

  • Integrated Surge Arrestors:
    0.6kV protection on excitation/transfer windings (IEEE C62.11 compliant)

  • Multi-Barrier Safety:

    • Triple-winding isolation (>1500 MΩ)

    • Oil dielectric stability (IEC 60296 standards)


Technical Validation Table

TestStandardPerformance
Partial DischargeIEC 60270System PD <5 pC
Temperature RiseIEEE C57.12.90Verified ≤65K winding
Impedance VoltageIEC 60076-1≤8% at 100kVA
Insulation ResistanceIEC 60060-3>1500 MΩ all paths

Industrial Applications

  • Cable Factory Acceptance: Extended 60-min tests per IEC 60502

  • Power Transformer Hipot: Commissioning tests (IEEE C57.12.00)

  • GIS Switchgear Validation: Sustained voltage application

  • High-Capacity Research: Material breakdown studies at industrial scale


Series Comparison

ModelCapacityKey AdvantageTarget Use Case
200kV/100kVA100kVAIndustrial enduranceCable/transformer factories
200kV/50kVA50kVABalanced power/sizeMedium-scale testing
200kV/20kVA20kVAPrecision PD controlCalibration labs
150kV/350kVA350kVAUltra-high current (4.8A)Short-circuit testing

Why This Transformer?

  • Highest 200kV Capacity: 2× more power than 50kVA model

  • Industrial Overload: 130% current handling for fault simulation

  • Silent Operation: ≤60dB for plant-floor environments

  • Oil Quality Assurance: #25 Chinese oil meets IEC 60296


Call to Action

For high-capacity testing solutions:
⚡ [Download 100kVA Test Protocols]
🔍 [Request Oil Analysis Report]
🏭 [Schedule Factory Witness Test]


>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message