High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

100kV ~ 400kV Range

LQTT Modular 150kV/75kVA Dual-Configuration Test Transformer | LQTT Series (Series/Parallel Operation)

Modular 75kVA HV test transformer: Operates at 150kV/0.5A (series) or 75kV/1A (parallel). Features <2pC PD, ONAN cooling & IEC compliance. Configurable for labs/field work. Get specs.


  • US$ 13,205.00
  • Lead time: 45 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

Technical Innovation Spotlight

The LQTT 150kV/75kVA redefines flexibility in high-voltage testing with dual-operation capability. Its modular design enables instant reconfiguration between series (150kV/0.5A) and parallel (75kV/1A) modes – ideal for multi-standard labs and field testing teams.


Core Specifications

ParameterValue
Modular Configuration2 identical modules
Series Mode150 kV / 0.5 A
Parallel Mode75 kV / 1.0 A
Rated Capacity75 kVA
Input Voltage0.4 kV
Frequency60 Hz
CoolingONAN (Oil-Natural Air-Natural)
Partial Discharge (PD)<2 pC at 100% UH (full system)
Waveform Distortion≤5%
Impedance Voltage≤10%
No-Load Current<10%
Dimensions (per module)≈850 mm × 1000 mm (confirm)
Weight (per module)<400 kg (estimate)

Performance Validation

1. Operational Resilience

  • 100% Rated Stress: 60 min operation at 150kV + 0.5A (series) or 75kV + 1A (parallel)

  • Continuous Duty: Unlimited operation at 120kV/0.4A (series) or 60kV/0.8A (parallel)

  • Thermal Limits:

    • Winding ΔT ≤ 65 K (vs. ambient)

    • Oil Surface ΔT ≤ 55 K

2. Precision Engineering

  • Ultra-Low PD: <2 pC at full voltage – exceeds IEC 60270 Type 2 requirements

  • Pure Waveform: ≤5% THD ensures accurate harmonics measurement

  • Low Impedance: ≤10% for stable output under load


Why Modular Design Matters

  1. Test Flexibility

    • Series: GIS/transformer withstand testing (150kV)

    • Parallel: Cable/breaker current-driven tests (1A)

  2. Transport Optimization

    • 400kg modules fit standard elevators/lifts

    • On-site assembly without cranes

  3. Redundancy

    • Single-module operation possible at 75kV/0.5A


Compliance & Safety

  • Dielectric Tests: IEC 60060-1/-2

  • Safety Standards: IEC 61010-1, IEC 61010-2-201

  • Environmental: IP54 enclosures (confirm)

  • Protections:

    • Overcurrent trip at 110% rated current

    • Oil temperature cut-off at 70°C


Configuration Scenarios

ApplicationRecommended ModeAdvantage
Cable PD DiagnosticsParallel (75kV/1A)Higher current sensitivity
Transformer Impulse TestSeries (150kV/0.5A)Full IEC 60076-3 compliance
Field CommissioningSingle Module75kV output with 50% weight

Technical Notes

ONAN Cooling: Zero maintenance, silent operation – ideal for lab environments
60Hz Optimization: Engineered for North American/Latin American markets
PD Superiority: <2pC enables detection of microscopic insulation defects