100kV ~ 400kV Range
Technical Innovation Spotlight
The LQTT 150kV/75kVA redefines flexibility in high-voltage testing with dual-operation capability. Its modular design enables instant reconfiguration between series (150kV/0.5A) and parallel (75kV/1A) modes – ideal for multi-standard labs and field testing teams.
Core Specifications
Parameter | Value |
---|---|
Modular Configuration | 2 identical modules |
Series Mode | 150 kV / 0.5 A |
Parallel Mode | 75 kV / 1.0 A |
Rated Capacity | 75 kVA |
Input Voltage | 0.4 kV |
Frequency | 60 Hz |
Cooling | ONAN (Oil-Natural Air-Natural) |
Partial Discharge (PD) | <2 pC at 100% UH (full system) |
Waveform Distortion | ≤5% |
Impedance Voltage | ≤10% |
No-Load Current | <10% |
Dimensions (per module) | ≈850 mm × 1000 mm (confirm) |
Weight (per module) | <400 kg (estimate) |
Performance Validation
1. Operational Resilience
100% Rated Stress: 60 min operation at 150kV + 0.5A (series) or 75kV + 1A (parallel)
Continuous Duty: Unlimited operation at 120kV/0.4A (series) or 60kV/0.8A (parallel)
Thermal Limits:
Winding ΔT ≤ 65 K (vs. ambient)
Oil Surface ΔT ≤ 55 K
2. Precision Engineering
Ultra-Low PD: <2 pC at full voltage – exceeds IEC 60270 Type 2 requirements
Pure Waveform: ≤5% THD ensures accurate harmonics measurement
Low Impedance: ≤10% for stable output under load
Why Modular Design Matters
Test Flexibility
Series: GIS/transformer withstand testing (150kV)
Parallel: Cable/breaker current-driven tests (1A)
Transport Optimization
400kg modules fit standard elevators/lifts
On-site assembly without cranes
Redundancy
Single-module operation possible at 75kV/0.5A
Compliance & Safety
Dielectric Tests: IEC 60060-1/-2
Safety Standards: IEC 61010-1, IEC 61010-2-201
Environmental: IP54 enclosures (confirm)
Protections:
Overcurrent trip at 110% rated current
Oil temperature cut-off at 70°C
Configuration Scenarios
Application | Recommended Mode | Advantage |
---|---|---|
Cable PD Diagnostics | Parallel (75kV/1A) | Higher current sensitivity |
Transformer Impulse Test | Series (150kV/0.5A) | Full IEC 60076-3 compliance |
Field Commissioning | Single Module | 75kV output with 50% weight |
Technical Notes
ONAN Cooling: Zero maintenance, silent operation – ideal for lab environments
60Hz Optimization: Engineered for North American/Latin American markets
PD Superiority: <2pC enables detection of microscopic insulation defects