100kV ~ 400kV Range
Technical Specifications
Parameter | Specification | Industry Significance |
---|---|---|
Rated Output | 150 kV / 1.0 A | Highest current in class |
Capacity | 150 kVA | |
Input Voltage | 0.4 kV | Direct grid connection |
Frequency | 50 Hz | Global compatibility |
Cooling | ONAN (Oil-Natural Air-Natural) | Zero-maintenance operation |
Partial Discharge | <5 pC at 100% UH | Exceeds IEC 60270 Type 1 |
Waveform Distortion | ≤5% | Critical for harmonics analysis |
Impedance Voltage | ≤10% | Short-circuit protection |
Overload Capacity | 150% current (225A) for 300s | Unique stress-test capability |
Thermal Rise (Winding) | ≤65 K | IEC 60076-11 compliant |
Thermal Rise (Oil) | ≤55 K | |
Weight | ≈200 kg | Lightest 150kVA in market |
Insulation Strength | 3 kV/min (LV to ground) | Enhanced safety margin |
Breakthrough Performance Features
1. High-Current Superiority
Industry-Leading 1A Output: Enables testing of low-impedance equipment (cables, busbars, switchgear)
Over-Current Resilience: 225A input (150% rated) for 5 minutes without insulation damage
Over-Voltage Tolerance: 165kV (110% rated) for 60 seconds
2. Thermal Management
Stable Duty Cycle:
60 min continuous operation at 150kV/1A
Unlimited operation at 120kV/0.8A (80% rating)
Optimized Cooling: Cylinder design enhances oil circulation (Ø850mm × 1000mm est.)
3. Safety Engineering
Enhanced Insulation: 3kV/min withstand on LV windings (exceeds IEC 61010 requirements)
ONAN Reliability: Mineral oil cooling eliminates fan dependency
Compact Design: 200kg weight enables lab mobility without cranes
Compliance & Testing Standards
Dielectric Tests: IEC 60060-1/-2
Safety Certification: IEC 61010-1, IEC 61010-031
Partial Discharge: IEC 60270 compliant
Routine Tests: Performed per IEC 60076-11
Application Matrix
Industry | Use Case | LQTT Advantage |
---|---|---|
Cable Manufacturers | HV cable type tests | 1A current for full-load simulation |
Utility Substations | Circuit breaker testing | 165kV overvoltage capability |
Aerospace | Insulation validation | <5pC PD sensitivity |
Renewable Energy | Solar farm combiner tests | 150kVA capacity for array simulation |
Technical Insights
Why 1A Output Matters:
Enables testing of high-capacitance loads (e.g., long cables) without voltage collapse - critical for IEC 60840 compliance.
Weight Revolution:
Advanced core materials (amorphous steel?) reduce weight by 40% vs conventional 150kVA units.
Overload Engineering:
Special duct cooling in windings allows 225A surges - ideal for motor/generator testing.
Competitive Advantage
Feature | LQTT 150kVA | Standard 150kVA |
---|---|---|
Rated Current | 1.0 A | 0.75-0.8 A |
Overload Duration | 300s at 150% | 60s typical |
Weight | ≈200 kg | 350-500 kg |
PD at 150kV | <5 pC | 10-15 pC |