100kV ~ 400kV Range
Technical Specifications Table
Parameter | Specification | Industry Benchmark |
---|---|---|
Rated Output | 150 kV / 0.67 A | Exceeds IEC 60060-2 Class 1 |
Capacity | 100 kVA | |
Input Voltage | 0.4 kV | Industrial standard |
Frequency | 50 Hz | Global compatibility |
Cooling | ONAN (Oil-Natural Air-Natural) | Zero-maintenance operation |
Partial Discharge | <5 pC at 100% UH | Surpasses IEC 60270 Type 1 |
Waveform Distortion | ≤5% | Critical for harmonics tests |
Impedance Voltage | ≤10% | Short-circuit protection |
No-Load Current | <10% | Energy-efficient design |
Thermal Rise (Winding) | ≤65 K | IEC 60076-11 compliant |
Thermal Rise (Oil) | ≤55 K |
Performance Highlights
1. Precision Engineering
Ultra-Clean Output: ≤5% waveform deviation ensures accurate dielectric loss measurements
Industry-Leading PD Sensitivity: <5pC detection at full 150kV for reliable insulation assessment
Stable Operation: ≤10% impedance voltage maintains voltage regulation under load
2. Robust Thermal Management
Overload Capability:
100% rated voltage & current for 60 minutes
Continuous operation at 120kV/0.54A (80% rating)
Thermal Safety Margins:
Winding ΔT ≤65K (ambient +65°C)
Oil ΔT ≤55K
3. Maintenance-Optimized Design
ONAN Cooling: Passive thermal management with mineral oil
Cylindrical Tank: Optimized oil circulation (Ø850mm × 1000mm est.)
Lightweight Construction: <500kg (est.) for lab mobility
Compliance & Certifications
Dielectric Testing: IEC 60060-1/-2
Safety Standards: IEC 61010-1, IEC 61010-031 (HV hand probes)
Environmental: IP55 protection (confirm)
Quality Assurance: Routine tests per IEC 60076-11
Application Scenarios
Type Testing Labs: Power transformer, GIS, cable compliance testing
Utility Substations: Circuit breaker withstand tests, insulation diagnostics
Manufacturing QC: Bushing, insulator, and surge arrester validation
Research Institutions: Dielectric material R&D at 150kV
Operational Advantages vs Competitors
Feature | LQTT 100kVA | Standard 100kVA |
---|---|---|
PD Level at 150kV | <5 pC | 10-20 pC |
Continuous Operation | 80% rating | 70% rating |
Thermal Recovery | 55K oil rise (8+ cycles) | 65K+ oil rise |
Weight | ~500kg (cylinder design) | 600-800kg |
Technical Insights
Why ≤5% Waveform Matters:
Ensures pure 50Hz sine wave for accurate power factor/tan-delta measurements - critical for cable aging assessment.
ONAN Cooling Superiority:
Eliminates fan failures in dusty environments. Oil volume: ≈300L (est.) for 55K thermal stability.
PD Testing Precision:
<5pC sensitivity detects microscopic voids in epoxy insulators at 150kV - prevents in-service failures.
CTAs for Conversion
▸ Download 150kV Test Protocols (IEC 60270/IEEE 4 templates)
▸ Request Custom Calibration Report
▸ Access Application Note: "Partial Discharge Testing at 100kVA"