150kV ~ 400kV
LQHDR Series: 150kV/1A High-Current Damping Resistor
Engineered for Demanding HV Applications
The LQHDR 150kV/5kΩ/1A damping resistor provides critical transient suppression in high-power systems. With 1A continuous current capacity and ultra-low partial discharge (<5pc), it="" ensures="" stable="" operation="" in="" 50hz="" power="" networks="" and="" industrial="" equipment.="">
Technical Specifications
Parameter | Specification | Testing Standard |
---|---|---|
Rated Voltage | 150kV AC/DC | IEC 60060-1 |
Rated Current | 1A Continuous | IEEE 62 |
Nominal Resistance | 5kΩ ±10% | MIL-R-26 |
Frequency | 50Hz (60Hz optional) | IEC 60270 |
Partial Discharge | <5pC @ rated voltage | IEC 60270 |
Operating Duration | 60 mins @ 100% load | ANSI C93.1 |
Temperature Rise | ≤80K at full load | IEC 60076 |
Dimensions | Ø250 × 1550mm | NEMA 250 |
Weight | <45kg | ASTM D642 |
Performance Advantages
High Current Capacity: 1A continuous rating for power-intensive applications
Ultra-Low PD: <5pC partial discharge ensures insulation integrity
Thermal Stability: Max 80K temperature rise at full load
Compact Design: Ø250mm profile for space-constrained installations
Rugged Construction: Corrosion-resistant housing (IP54 rated)
Industry Applications
High-Power Test Laboratories
Damps oscillations in 150kV impulse generators during dielectric testing per IEC 61083-2.
Utility Substations
Suppresses switching transients in 138kV+ capacitor banks and circuit breakers.
Industrial Rectifier Systems
Controls voltage spikes in HV DC power supplies for electrolysis processes.
Medical Imaging Equipment
Stabilizes X-ray tube circuits in 150kV generator systems.
Installation Guidelines
Maintain minimum 600mm clearance from grounded surfaces
Ensure ambient temperature ≤40°C (derate 2.5%/°C above)
Use corona shields for installations above 100kV
Verify creepage distance ≥30mm/kV (per IEC 60664-1)
Mount vertically for optimal convection cooling
Compliance & Safety
Partial discharge: IEC 60270 compliant
Dielectric strength: 250kV lightning impulse withstand
Environmental: IP54 protection (dust/water resistant)
Safety factor: 200% rated voltage for 1 minute
Flame resistance: UL94 V-0 rated materials
Maintenance Protocol
Interval | Procedure | Acceptance Criteria |
---|---|---|
Monthly | Infrared thermal scan | ΔT ≤ 15K above ambient |
Quarterly | Resistance measurement | 5kΩ ±10% |
Annual | Dielectric test | Pass 150kV/1 min |
24 Months | Full calibration | NIST-traceable cert |