150kV ~ 400kV
LQHDR Series: 150kV/15kΩ High-Precision Damping Resistor (265W)
Optimized for Cyclic High-Voltage Applications
Engineered for precision power management, the LQHDR 150kV/15kΩ/0.133A damping resistor delivers 265W of stable transient suppression. With its specialized cyclic operation profile (8 cycles/day max) and ultra-low partial discharge (LT 5pC), it's ideal for intermittent high-voltage systems requiring precise energy dissipation.
Technical Specifications
Parameter | Specification | Standard |
---|---|---|
Rated Voltage | 150kV AC/DC | IEC 60060-1 |
Rated Current | 0.133A Continuous | IEEE 62 |
Nominal Resistance | 15kΩ ±5% | MIL-R-26 |
Rated Power | 265W | IEC 60115 |
Frequency | 50Hz (60Hz optional) | IEC 60270 |
Partial Discharge | <5pC @ 150kV | IEC 60270 |
Operating Cycle | 30min ON / 60min OFF | ANSI C93.1 |
Daily Cycles | 8 maximum | IEC 60076 |
Temperature Rise | ≤80K at full load | IEC 60076 |
Dimensions | Ø80 × 950mm | NEMA 250 |
Weight | 15kg | ASTM D642 |
Key Performance Features
Precision Power Handling: 265W continuous rating with ±5% resistance tolerance
Ultra-Low PD: <5pC partial discharge ensures insulation integrity
Cyclic Operation: Optimized for 30min ON/60min OFF duty cycles
Compact Design: Ø80mm profile fits space-limited installations
Thermal Management: 80K max temperature rise with forced convection design
Targeted Applications
Pulsed Power Systems
Damps transients in capacitor discharge circuits for laser and plasma generators.
Medical Radiation Therapy
Stabilizes linear accelerator (LINAC) power supplies in cancer treatment equipment.
Industrial X-Ray Inspection
Suppresses voltage spikes in 150kV non-destructive testing systems.
Research Accelerators
Provides precision damping for particle beam control systems.
Cyclical Operation Protocol
Standard Operating Profile
Maximum 8 cycles per day with each cycle consisting of:
30 minutes: Full-load operation at 150kV/0.133A
60 minutes: Mandatory cooling period
Exceeding 8 cycles requires 12-hour system rest.
Thermal Monitoring
Infrared sensors should verify surface temperature ≤110°C during operation. Automatic shutdown required at 120°C.
Installation Guidelines
Maintain minimum 500mm clearance to grounded surfaces
Ensure ambient temperature ≤35°C (derate 3%/°C above)
Install vertical orientation with ±2° tolerance
Use corona rings for connections above 100kV
Verify creepage distance ≥35mm/kV (per IEC 60664-1)
Compliance & Safety
Partial discharge: IEC 60270 compliant
Impulse withstand: 250kV (1.2/50μs wave)
Environmental rating: IP55 (dust/water protected)
Safety margin: 180% rated voltage for 1 minute
Flame resistance: UL94 V-0 certified housing
Maintenance Protocol
Interval | Procedure | Acceptance Criteria |
---|---|---|
After 50 cycles | Resistance verification | 15kΩ ±5% |
Quarterly | Infrared thermography | ΔT ≤ 80K at full load |
Biannual | Dielectric strength test | Pass 180kV AC/1 min |
500 cycles | Full recalibration | NIST-traceable certificate |