High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

>1600KV Range

LQHIVG 3600KV-540KJ High-Energy Impulse Generator: Technical Specifications & Waveform Compliance

Technical specifications for the LQHIVG 3600KV-540KJ Impulse Generator with IEC/IEEE compliance, lightning/switching impulse waveforms, and efficiency parameters for high-voltage testing.


  • US$ 180,328.00
  • Lead time: 120 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHIVG 3600KV-540KJ High-Energy Impulse Generator: Technical Specifications & Waveform Compliance

Ultra-High Energy Impulse Testing System

Engineered for maximum energy delivery, the LQHIVG 3600KV-540KJ sets new benchmarks in high-voltage impulse testing. Compliant with IEC 60060-1/2 and IEEE 4 standards, its 540kJ capacity supports critical infrastructure testing for utilities and certification labs.

Core Technical Specifications

ParameterSpecification
Rated Voltage±3600kV
Stage Voltage±200kV
Charging Voltage±100kV
Rated Energy540kJ
Stages18 stages
Stage Capacitors18 × 1.5μF/200kV
Stage Energy30kJ
Voltage Stability<±1.0% fluctuation
Physical Dimensions13.5m height / 13,000kg weight

Precision Waveform Generation

Standard Waveforms (IEC 60060-1)

  • Lightning Impulse (Full Wave):

    • 1.2μs ±30% / 50μs ±20%

    • Peak oscillation <5%

    • Amplitude tolerance: +3%

  • Switching Impulse: 250μs ±20% / 2500μs ±60%

  • Chopped Wave: 2-5μs chop time (±100ns dispersion)

Compliant with GB311 & GB16927 deviation requirements.

Voltage Utilization Efficiency

Test TypeConditionEfficiency
Lightning ImpulseNo load≥90%
Lightning Impulse3000pF load≥85%
Switching Impulse1000pF load≥70%
Switching Impulse3000pF load≥60%

Operational Control System

  • Voltage Range: 15%-100% Un

  • Synchronization:

    • 20%-100% stage voltage range

    • <20% polarity variance

    • <2% out-of-control rate

  • Duty Cycle:

    • >70% Un: 120s charge/discharge

    • <70% Un: 90s charge/discharge

  • Voltage Control:

    • Charging instability <±1.0%

    • Reference deviation <±1.0%

Compliance & Certification

  • IEC 60060-1/2 (2010): High-voltage test techniques

  • IEC 61083-1/2: Digital measurement instruments

  • ANSI/IEEE 4a (2001): Testing techniques

  • IEEE 376 (1975): Impulse strength measurement

  • ASTM D2518 (Latest): Insulation testing

Industrial Applications

  • Ultra-high-voltage (UHV) transformer testing

  • GIS substation equipment certification

  • HVDC transmission component validation

  • Renewable energy grid interconnection testing