>1600KV Range
HIVG 2800KV-420KJ Impulse Voltage Generator: High-Energy Testing Solution
Ultra-High Voltage Testing System
The HIVG 2800KV-420KJ Impulse Voltage Generator represents the pinnacle of high-voltage testing technology. With its 14-stage architecture and massive 420kJ energy capacity, this system generates precise lightning impulses, switching surges, and chopping waves up to 2800kV for critical equipment validation in power transmission and industrial applications.
Technical Specifications
Parameter | Specification |
---|---|
Rated Voltage | +2800kV |
Rated Energy | 420kJ |
Stages | 14 stages |
Stage Voltage | +200kV |
Charging Voltage | +100kV |
Generator Capacitance | 0.125μF (28 x 100kV/3μF units) |
Generator Dimensions | Height: 10550mm, Weight: 11200kg |
Minimum Output Voltage | >10% UH |
Precision Waveform Generation
1. Lightning Impulse Wave (IEC 60060-1)
Waveform: 1.2μs ±30% / 50μs ±20%
Peak Oscillation: ≤5% amplitude
2. Switching Impulse Wave
Waveform: 250μs ±20% / 2500μs ±60%
3. Lightning Impulse Chopping Wave
Chopping Time: 2-6μs
Standard Deviation: <±0.2μs
Performance Metrics
Voltage Utilization Factor:
Lightning Impulse: ≥90% at no-load
Switching Impulse: ≥65% at 3000pF load
Synchronization: ±20% range at 20-100% rated voltage
Discharge Control: <2% uncontrolled rate
Voltage Stability: Charging fluctuation <±1.0%
Sparking Range: 10-100% UH
Duty Cycle:
120s cycle at >70% rated voltage
90s cycle at <70% rated voltage
Compliance with International Standards
IEC 60060-1/2 (2010): High-voltage test definitions & procedures
IEC 61083-1/2: Instrumentation for impulse measurements
ANSI/IEEE 4a, 376, 1122: Impulse strength measurement
ASTM D2484/D2518: Electrical insulation standards
GB311/GB16927: Chinese national testing requirements
Industrial Applications
Ultra-high voltage transformer testing
Power grid protection system validation
Insulation coordination studies (IEC 60071)
High-capacity surge arrester verification
Research & development of next-generation HV equipment