LQHCR 500KVA-3KV Adjustable Compensation Reactor: Technical Specifications & Industrial Applications

Complete technical specifications for LQHCR 500KVA-3KV adjustable compensation reactor with 100-500kVar continuous control. Explore safety features and industrial applications.


  • US$ 9,836.00
  • Lead time: 45 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHCR 500KVA-3KV Adjustable Compensation Reactor: Technical Specifications & Industrial Applications

Product Overview

The LQHCR 500KVA-3KV is a stationary iron core compensation reactor designed for precision reactive power management in medium-voltage systems. Featuring continuous 100-500kVar adjustability, it provides dynamic power factor correction and harmonic suppression in industrial power networks.

Technical Specifications

ParameterSpecification
ModelLQHCR 500KVA-3KV
StructureIron shell, stationary iron core
Rated Capacitance500kVar
Adjustment Range100kVar - 500kVar continuous
Rated Frequency50Hz
Phase ConfigurationSingle phase
Rated Voltage3kV
Rated Current Range33.3A - 166.6A
Linearity Degree< +1%
Sound Level< 70dB (measured at 4 meters)
Continuous Operation60 minutes at rated voltage/current

Advanced Safety Features

Over-Current Protection

Withstands 120% of rated current for 10 minutes without thermal damage or winding distortion.

Over-Voltage Protection

Handles 110% of rated voltage for 10 minutes without insulation compromise.

Key Performance Advantages

  • Precision Adjustment: Continuous 100-500kVar control enables real-time power optimization

  • Ultra-Linear Response: <+1% deviation ensures accurate harmonic filtering

  • Low Acoustic Profile: <70dB operation meets strict facility noise requirements

  • Robust Thermal Design: Iron shell construction with optimized heat dissipation

Industrial Applications

Manufacturing Plants

Dynamic compensation for variable motor loads and welding equipment

Data Centers

Harmonic suppression in 3kV UPS and backup power systems

Renewable Energy

Stabilizing grid connections for solar/wind farms with fluctuating output

Mining Operations

Power factor correction for high-torque extraction equipment

Installation Guidelines

  1. Maintain minimum 500mm clearance from adjacent equipment

  2. Ensure ambient temperature <40°C and humidity <85% RH

  3. Verify base frame levelness within ±1mm/m

  4. Implement Class II insulation coordination per IEC 60664

Maintenance Protocol

Maintenance TaskFrequencyStandard
Insulation resistance testQuarterlyIEC 60270
Winding temperature checkMonthlyIEEE C57.96
Core saturation testAnnuallyIEC 60404
Full calibrationBienniallyISO/IEC 17025

Compliance Standards

  • IEC 60289: Reactor specifications

  • IEEE C57.12.00: Safety requirements

  • EN 50588: Industrial reactor standards

  • GB 1094.6: Reactor testing protocols