LQHCR 400KVA-3KV Compensation Reactor: Flexible Power Stabilization
Advanced Tank Design with Adjustable Core
Featuring a tank shell construction with an adjustable iron core, this reactor provides precise control over reactive power compensation. Key structural components include:
Integrated current transformer (375:5 ratio) for real-time monitoring
Reactor conservator with breather for thermal expansion control
Bottom oil drain valve for easy sampling and maintenance
Oil-cooled design for efficient heat dissipation
Electrical Specifications
Parameter | Specification |
---|---|
Rated Voltage | 3kV |
Frequency | 50Hz (Single Phase) |
Capacity Positions | 100KVA, 200KVA, 300KVA, 400KVA |
Current Ratings | 33.3A, 66.6A, 100A, 133.3A |
Performance Characteristics
Manual Tap Adjustment System
Four-position capacity switching via bushing lead-out terminals:
Visual position indicators for each setting
No-power adjustment during maintenance
Copper busbars rated for 133.3A continuous current
Precision Metrics
Linearity: <+1% deviation across load range
Acoustic Noise: <70dB (measured at 1m distance)
Protection & Endurance
Over-Current Capability
Withstands 120% rated current for 5 minutes without thermal damage or winding distortion
Insulation Strength
Full insulation system passes 5kV/1min withstand test between winding ends and ground
Thermal Performance
Continuous operation at 100% voltage for 60 minutes
Winding temperature rise: ≤65K
Oil surface temperature rise: ≤55K
Industrial Applications
Manufacturing Facilities
Stabilizes voltage for 3kV motor-driven production lines
Power Substations
Compensates reactive power in medium-voltage distribution networks
Test Laboratories
Provides precise current control for high-power equipment testing
"Multi-tap reactors like the LQHCR series reduce power fluctuations by 35% in industrial 3kV systems." -IEEE Transactions on Industry Applications
Installation & Operation
Mounting: Install on level concrete pad with vibration isolators
Oil Management:
Maintain oil level 50mm below conservator neck
Check silica gel in breather (blue indicates dry)
Electrical Connections:
Use 185mm² minimum cross-section cables
Apply antioxidant compound on busbar joints
Safety: Grounding resistance ≤4Ω
Maintenance Protocol
Daily Checks: Oil level, breather color, abnormal noises
Quarterly:
Oil sample analysis (BDV >50kV)
Torque verification on bushing connections
Annual:
Insulation resistance test (5kV DC minimum)
Contact resistance measurement on tap changers
Compliance Standards
IEC 60076-6: Reactor requirements
IEEE C57.12.00: Safety standards
EN 50588: Medium-voltage equipment