≤600KVA Range
LQHCR 400KVA-0.6KV Compensation Reactor: High-Current Power Correction
Robust Iron-Core Construction
Featuring a stationary iron core within an iron shell structure, this reactor delivers exceptional stability for high-current applications. The optimized magnetic circuit minimizes losses while providing mechanical rigidity in demanding 0.6kV industrial environments.
Electrical Specifications
Parameter | Specification |
---|---|
Rated Power | 400KVA |
Rated Voltage | 0.6kV (parallel/serial configurable) |
Output Current Range | 66.66A to 666.6A |
Frequency | 50Hz |
Phase Configuration | Single Phase |
Flexible Connection Options
Parallel Connection Mode
Ideal for high-current applications (up to 666.6A) in heavy industrial equipment
Serial Connection Mode
Optimized for voltage-sensitive systems requiring precise reactive power control
Performance Excellence
Linearity: <+1% deviation across entire operational range
Acoustic Performance: Ultra-quiet <65dB operation (measured at 4m distance)
Thermal Management:
Winding temperature rise: ≤65K
Oil surface temperature rise: ≤55K
Advanced Protection Capabilities
Over-Current Endurance
Sustains 120% rated current for 10 minutes without thermal damage or winding distortion
Over-Voltage Tolerance
Withstands 110% rated voltage for 10 minutes without insulation failure
Continuous Operation
Maintains 100% rated voltage for 60 minutes with temperature rise within strict safety limits
Industrial Applications
Foundries & Smelters
Stabilizes power for induction furnaces and high-current processing equipment
Data Center Power Systems
Compensates reactive power in UPS and backup generator systems
EV Manufacturing
Manages harmonic distortion in battery pack testing stations
"Iron-core reactors with 666A+ capacity reduce energy losses by 18-22% in low-voltage industrial networks." -IEEE Transactions on Industry Applications
Installation Guidelines
Connection Selection:
Parallel for currents above 300A
Serial for voltage stabilization requirements
Thermal Management:
Maintain 600mm clearance around unit
Ambient temperature ≤40°C
Electrical Requirements:
For 666A operation: 2x300mm² parallel copper busbars
Grounding resistance ≤4Ω
Maintenance Protocol
Monthly:
Infrared thermal scan of connections
Oil level inspection
Quarterly:
Insulation resistance test (min 100MΩ at 2.5kV DC)
Terminal torque verification
Annual:
Oil dielectric strength test (BDV >45kV)
Core clamping force measurement
Compliance Standards
IEC 60289: Reactor performance standards
EN 60076-6: Thermal performance requirements
ANSI C57.16: Low-voltage reactor specifications