LQHCR 350KVA-0.6KV Dual-Current Compensation Reactor: Technical Specifications & Industrial Applications

Technical specifications for LQHCR 350KVA-0.6KV Compensation Reactor with dual current outputs (583.3A/1166.6A) and integrated 300:5 current transformer.


  • US$ 7,334.00
  • Lead time: 45 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHCR 350KVA-0.6KV Dual-Current Compensation Reactor: Technical Specifications & Industrial Applications

Core Electrical Parameters

ParameterSpecification
Rated Capacity350kVA
Rated Voltage0.6kV
Frequency50Hz
Phase ConfigurationSingle Phase
Current Outputs583.3A / 1166.6A (dual-range)
Current Transformer300:5 ratio (built-in)

Dual-Current Operation System

Low Range (583.3A)

  • Optimal for medium industrial loads

  • Higher impedance configuration

  • Ideal for continuous operation

High Range (1166.6A)

  • Designed for peak industrial demands

  • Lower impedance for heavy loads

  • Short-term overload capability

Switching Mechanism: Solid-state contactors with arc suppression for live switching

Integrated Monitoring System

  • Current Transformer: 300:5 ratio provides precise compensation monitoring

  • Thermal Sensors: Embedded in core and windings (Class B temperature class)

  • Digital Interface: MODBUS RTU protocol for SCADA integration

Performance Specifications

ParameterValue
Over-current Capacity120% rated current for 10 minutes
Over-voltage Capacity110% rated voltage for 10 minutes
Linearity<±1% deviation (full range)
Total Harmonic Distortion<2.5% at full load
Sound Level<70dB at 4m distance

Industrial Applications

  1. Steel Manufacturing: Power factor correction for arc furnaces

  2. Chemical Plants: Reactive power compensation for large motor drives

  3. Data Centers: Voltage stabilization in high-density server farms

  4. Renewable Energy: Grid stabilization for wind farm substations

  5. Mining Operations: Harmonic filtering for excavator power systems

Installation Specifications

ParameterRequirement
Ambient Temperature-25°C to +50°C
Altitude<1000m ASL (derate 1.5% per 100m above)
Humidity<95% RH (non-condensing)
Clearance Space800mm minimum around unit
FoundationReinforced concrete ≥200mm

Compliance Standards

  • IEC 60289: Reactors for AC power systems

  • IEEE C57.12.01: Dry-type transformer requirements

  • EN 50588-1: Medium power transformers

  • IEC 61000-3-6: Harmonic emission standards

  • Safety Certification: UL 508A (Industrial Control Equipment)

Maintenance Protocol

  1. Monthly:

    • Visual inspection of cooling vents

    • Thermal scan of connections

  2. Quarterly:

    • Insulation resistance test (5kV DC Megger)

    • Current transformer calibration check

  3. Annual:

    • Winding resistance measurement

    • Core excitation test

    • Dielectric absorption test

Safety Notice: De-energize for 15 minutes before servicing. Use CAT III PPE for 600V systems.

Technical Advantages

  • Dual-range Flexibility: Adapts to varying load conditions without hardware changes

  • High Current Capacity: 1166.6A output suitable for heavy industrial applications

  • Integrated Monitoring: Built-in CT eliminates external measurement devices

  • Robust Construction: Industrial-grade components for 24/7 operation