High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

High Voltage Insulation Equipment

LHV-283 Automatic Water Injection Insulating Boots/Gloves Tester | 8-Channel HV Test System

Fully automatic 8-channel insulation tester with PLC-controlled water injection system complies with DLT 976-2017/GBT 17622-2008. Features touchscreen interface, lithium-powered current monitoring, and automated test sequences.


  • US$1.00; Negotiated Price
  • Lead time: 60days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LHV-283 Automatic Water Injection Insulating Boots/Gloves Voltage Withstand Device

Intelligent 8-Channel Insulation Testing System

This PLC-controlled device performs automated dielectric tests on up to 8 insulating gloves or boots simultaneously, featuring precision water injection technology and real-time leakage current monitoring for high-voltage safety equipment.

Product Parameters

Technical Parameters

Device output voltage rangeAC 0~50kV (0~250V)
Rated output capacity of the device5kVA
Device input current0~20A
Leakage current measurement range0~30.0mA (0~50mA can be customized)
Leakage current measurement error1%±3 words
Leakage current resolution0.01 mA
Voltage measurement error≤1% indication value ±0.1% range
Current measurement error≤1% indication value ±0.1% range
Digital display timing0 ~ 999S
Overall dimensions of console1300×940×860mm3
Dimensions of the water injection unit1900×950×1860mm3
Console weight50kg
Injection weight200kg

Compliance Standards

  • DLT 976-2017 - Live working tools test procedures

  • DLT 1476-2015 - Electrical safety appliances testing

  • GBT 17622-2008 - Insulating gloves specifications

  • CB21148:2020 - Foot protection safety requirements

Key Features

1. High-Capacity Testing

Simultaneously tests 8 insulating gloves/boots with individual leakage current measurement (0.5mA resolution)

2. Smart Water Injection System

Automatically adjusts water levels according to:

  • Glove cuff-to-water surface distance per DL/T1476-2015

  • Internal/external water level synchronization

3. Dry Test Methodology

Steel ball-filled boots eliminate traditional water immersion:

  • Sponge-lined test tank for stability

  • Auto-fill water jacket system

4. Advanced PLC Control

One-touch operation with:

  • Test position detection

  • Multi-level water sensing

  • Automatic system reset

5. Wireless Monitoring System

Lithium-powered collection box features:

  • 8-channel leakage sampling

  • Battery percentage display

  • LED current readouts (0-20mA range)

6. Instant Trip Protection

Electromagnet/spring mechanism:

  • Isolates faulty units in <2ms

  • Adjustable current thresholds

Technical Specifications

ParameterSpecification
Test Capacity8 units simultaneously
Control SystemIndustrial PLC with touchscreen
Voltage RegulationStepper motor-controlled (0.5% accuracy)
DisplayDual LCDs showing:
  • Test voltage

  • 8-channel leakage currents

  • Timing parameters

SoftwarePC interface for:
  • Remote control

  • Data logging

  • Report generation

Automated Test Sequence

  1. Position test specimens in designated holders

  2. Select test parameters via touchscreen

  3. System auto-fills water to precise levels

  4. Programmable voltage ramp-up (per standards)

  5. Timed dwell at test voltage

  6. Automatic ramp-down and shutdown

  7. Results displayed with pass/fail indication

Industry Applications

  • Utility Companies - PPE compliance testing

  • Electrical Contractors - Monthly safety checks

  • Manufacturing Plants - Quality assurance testing

  • Safety Inspectors - Certification verification

Recommended test frequency: 6 months per international standards

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message