High Voltage Insulation Equipment
LDL Series Fully Automatic Temperature Rise Test Device
High-Current Testing Solution for Electrical Equipment
Designed for temperature rise tests on high-voltage switches, transformers, and electrical components. Complies with GB/T 16927.4-2014 for industrial, laboratory, and power utility applications.
Product Parameters
Technical Parameters
Input Voltage | Three-phase four-wire AC380V |
Rated Frequency | 50Hz |
Total System Power | 189kW |
Total System Current | 287A |
System Power Factor | cos²=0.8 |
Oil-Immersed Induction Voltage Regulator
Rated Capacity | 63kVA |
Output Voltage | 0-430V |
Output Current | 0-166A |
Waveform Distortion | ≤3% |
Starting Voltage | ≤1% |
Short-Circuit Impedance | ≤7% |
Dry-Type Current Booster
Rated Capacity | 63kVA |
Output Line Voltage | 10V |
Output Current | 0-6300A |
Rated Input Voltage | 380V |
No-Load Loss | <4% |
Rated Input Current | 166A |
Short-Circuit Impedance | ≤5% |
Cooling Method | Dry-type, air-cooled |
Key Features:
Fully Automated: No manual intervention required
0.5% Current Accuracy: Computer-monitored output
Real-time active power display
Zero-start safety protection
System Components
Core Modules
Auto-Current Regulator: Compensates for deviations
Digital Power Meter: Real-time input/output monitoring
Safety Interlocks: Overcurrent/over-temperature protection
Control Interface
PC software for parameter setting
Graphical current/power trending
Test duration timer with alarms
Testing Workflow
Connect test specimen
Set target current via software
Initiate automated test sequence
Monitor real-time data
System auto-terminates upon completion
Applications
Test Objects
High-voltage circuit breakers
Busbars and switchgear
Transformer windings
Cable joints/terminations
User Sectors
Power generation plants
Electrical manufacturers
Certification laboratories
Industrial maintenance teams
Safety & Compliance
Protection Features
Zero-voltage start prevention
Automatic emergency cutoff
Isolated control circuitry
Standards Met
GB/T 16927.4-2014
IEC 60439-1 (switchgear assemblies)
ANSI C37.09 (circuit breaker testing)
Control Software Capabilities
Current waveform recording
Temperature vs. time graphing
Test report generation
Calibration mode