High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

High Voltage Insulation Equipment

LVLF Hipot Test Set | 0.1Hz Ultra-Low Frequency Voltage Tester for Large Capacitance Equipment

The LVLF Hipot Test Set performs 0.1Hz ultra-low frequency voltage tests on cables, generators, and transformers. Features touchscreen control, no capacitive lift effect, and full compliance with DL/T 849.4-2004 standards.


  • US$1.00; Negotiated Price
  • Lead time: 90days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LVLF Hipot Test Set: Advanced 0.1Hz Ultra-Low Frequency Voltage Testing

The LVLF Hipot Test Set revolutionizes insulation testing for high-capacitance equipment like power cables and generators. Utilizing 0.1Hz ultra-low frequency (ULF) technology compliant with DL/T 849.4-2004, it replaces bulky power frequency testers with a portable, intelligent solution.

Product Parameters

Technical parameter

Power supplyAC220V±5%, 50/60Hz. If using a generator, it must be a digital inverter generator with 220V output and power >8kW. Ordinary generators or UPS power supplies are prohibited.
Output Voltage30kV, 40kV, 50kV, 60kV, 70kV, 80kV, 80kV, 90kV
Output frequency0.1Hz, 0.05Hz, 0.02Hz,0.01Hz
Load Capacity0.1Hz-0.5μF, 0.05Hz-1.0μF,0.02Hz-2.5μF,0.01Hz-5μF
Measurement accuracy3%
Voltage positive,negative peak error≤3%
Voltage waveform distortion≤5%
Operating EnvironmentTemperature: -10℃~+40℃
Humidity≤85%RH

Ultra-low frequency series products

Model numberRated voltageCarrying capacityPower supply fuseGenerator powerProduct structure, weight
30/1.130kV(peak)0.1Hz, ≤1.1μF10A>3kWController: 4kg, booster: 25kg
0.05Hz,≤2.2μF
0.02Hz,≤5.5μF
0.01Hz,≤11μF
VLF-40kV40kV(peak)0.1Hz,≤0.8μF15A>4kWController: 4kg, booster: 25kg
0.05Hz,≤1.6μF
0.02Hz,≤4μF
0.01Hz,≤8μF
VLF-50kV50kV(peak)0.1Hz,≤0.7μF20A>5kWController: 4kg, booster: 35kg
0.05Hz,≤1.4μF
0.02Hz,≤3.5μF
0.01Hz,≤7μF
VLF-60kV60kV(peak)0.1Hz,≤0.6μF20A>6kWController: 4kg, booster: 45kg
0.05Hz,≤1.2μF
0.02Hz,≤3μF
0.01Hz,≤6μF
VLF-80kV80kV(peak)0.1Hz,≤0.5μF30A>8kWController: 4kg, booster: 50kg
0.05Hz,≤1.0μF
0.02Hz,≤2.5μF
0.01Hz,≤5μF
VLF-90kV90kV(peak)0.1Hz,≤0.4μF30A>9kWController: 4kg, booster: 55kg
0.05Hz,≤.0.8μF
0.02Hz,≤2.0μF
0.01Hz,≤4μF

Comparison of mechanical and electronic performance of 0.1Hz voltage test equipment



0.1Hz Voltage resistant device typeHigh pressure control systemHigh voltage waveformEnergy saving noiseMechanical lifeElectrical life
Mechanical typeHigh voltage mechanical switch toggles polaritySquare waveNo energy saving: the excess energy is consumed with high-power resistancehighshortshort
Electronic typeHigh voltage electronic switches switch polaritySinusoidal waveEnergy conservation: Excess power is fed back into the gridslightThere is nolong

Performance comparison of various pressure test equipment

Comparative contentPower frequency withstand voltageVariable frequency voltage resistanceWithstand voltage 0.1HzDc voltage resistance
equivalencegoodgoodgoodIn general
Insulation destructivenesssmallsmallsmalllarger
Operational safetylowerlowerhighlower
Test connectioncomplexcomplexsimplesimple
Equipment volumemaximumlargersmallsmall

Why Choose 0.1Hz ULF Technology?

  • 500% Capacity Reduction vs. power frequency tests (per IEC recommendations)

  • Equivalent Accuracy: Matches 50Hz test results with 90% smaller equipment

  • Ideal for High-Capacitance Loads: Cables, generators, and transformers

Key Features

FeatureAdvantage
7" Touchscreen ControlFully automated tests with one-touch operation
Closed-Loop FeedbackEliminates capacitive lift effect (±0.5% stability)
Multi-Frequency Selection0.01Hz, 0.02Hz, 0.05Hz, and 0.1Hz modes
Nanosecond ProtectionOvervoltage/overcurrent protection (≤10ms response)

Applications

  • XLPE Power Cables: 35kV and below (per DL/T 849.4-2004)

  • Generators & Motors: Insulation tests without massive resonant transformers

  • Field Testing: 50% lighter than conventional testers

Technical Specifications

  • Frequency Range: 0.01Hz–0.1Hz

  • Voltage Accuracy: ±(1% reading + 1V)

  • Data Sampling: High-voltage side direct measurement

  • Safety Standards: IEC 61010, DL/T 849.4-2004

Competitive Advantages

  1. Imported Components: High-speed AD circuits for precise measurements

  2. User-Friendly Design:

    • Bilingual interface (Chinese/English)

    • Automatic report generation

  3. Reliability: 30% lower failure rate vs. mechanical boosters

Contact us for OEM services or bulk procurement discounts.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<